A Time Domain Fluorescence Tomography System for Small Animal Imaging
- 8 February 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 27 (8) , 1152-1163
Abstract
We describe the application of a time domain diffuse fluorescence tomography system for whole body small animal imaging. The key features of the system are the use of point excitation in free space using ultrashort laser pulses and noncontact detection using a gated, intensified charge-coupled device (CCD) camera. Mouse shaped epoxy phantoms, with embedded fluorescent inclusions, were used to verify the performance of a recently developed asymptotic lifetime-based tomography algorithm. The asymptotic algorithm is based on a multiexponential analysis of the decay portion of the data. The multiexponential model is shown to enable the use of a global analysis approach for a robust recovery of the lifetime components present within the imaging medium. The surface boundaries of the imaging volume were acquired using a photogrammetric camera integrated with the imaging system, and implemented in a Monte-Carlo model of photon propagation in tissue. The tomography results show that the asymptotic approach is able to separate axially located fluorescent inclusions centered at depths of 4 and 10 mm from the surface of the mouse phantom. The fluorescent inclusions had distinct lifetimes of 0.5 and 0.95 ns. The inclusions were nearly overlapping along the measurement axis and shown to be not resolvable using continuous wave (CW) methods. These results suggest the practical feasibility and advantages of a time domain approach for whole body small animal fluorescence molecular imaging, particularly with the use of lifetime as a contrast mechanism.Keywords
This publication has 77 references indexed in Scilit:
- Free-space fluorescence molecular tomography utilizing 360° geometry projectionsOptics Letters, 2007
- Design, Synthesis, and Evaluation of Near Infrared Fluorescent Multimeric RGD Peptides for Targeting TumorsJournal of Medicinal Chemistry, 2006
- Laguerre-based method for analysis of time-resolved fluorescence data: application to in-vivo characterization and diagnosis of atherosclerotic lesionsJournal of Biomedical Optics, 2006
- Three‐dimensional fluorescence lifetime tomographyMedical Physics, 2005
- Whole-body fluorescence lifetime imaging of a tumor-targeted near-infrared molecular probe in miceJournal of Biomedical Optics, 2005
- Experimental Fluorescence Tomography of Tissues With Noncontact MeasurementsIEEE Transactions on Medical Imaging, 2004
- A comparison of exact and approximate adjoint sensitivities in fluorescence tomographyIEEE Transactions on Medical Imaging, 2003
- Diffuse Optical Tomography of Cerebral Blood Flow, Oxygenation, and Metabolism in Rat during Focal IschemiaJournal of Cerebral Blood Flow & Metabolism, 2003
- Optical tomography in medical imagingInverse Problems, 1999
- Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical propertiesApplied Optics, 1989