Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study
Open Access
- 24 February 2023
- journal article
- research article
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (3) , 124
Abstract
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts. The first part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5), a 15° access channel with a specially designed zirconia crown (sASC-15) (n = 5), and a 25° access channel with a specially designed zirconia crown (sASC-25) (n = 5). The reverse torque value (RTV) was measured at 0° for each specimen. The second part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5); a 15° access channel with a zirconia crown (ASC-15) (n = 5), and a 25° access channel with a zirconia crown (ASC-25) (n = 5). The manufacturer’s recommended torque was applied to each specimen, and baseline RTV was measured before cyclic loading. Each ASC implant assembly was cyclically loaded at 0 to 40 N with 1 million cycles at 10 Hz. RTV was measured after cyclic loading. Kruskal–Wallis test and Jonckheere–Terpstra test were used for statistical analysis. All specimens were examined under a digital microscope and scanning electron microscope (SEM) to observe the wear of the screw head before and after the whole experiment. A significant difference in the different percentages of straight RTV (sRTV) between the three groups was found (p = 0.027). The angle of ASC to the different percentages of sRTV showed a significant linear trend (p = 0.003). No significant differences were found in RTV difference after cyclic loading among the ASC-0, ASC-15, and ASC-25 groups (p = 0.212). The ASC-25 group had the most serious degree of wear based on a digital microscope and SEM examination. The ASC angle will affect the actual preload acting on a screw: the larger the ASC angle, the smaller the preload. The performance of the angled ASC groups in RTV difference was comparable to that of 0° ASC after cyclic loading.Keywords
Funding Information
- Chang Gung Medical Foundation and Cheng Shiu University (CMRPG8K0181)
This publication has 42 references indexed in Scilit:
- Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow‐up of 5 yearsClinical Oral Implants Research, 2012
- Cemented and screw‐retained implant reconstructions: a systematic review of the survival and complication ratesClinical Oral Implants Research, 2012
- Effects of Abutment Screw Coating on Implant PreloadJournal of Prosthodontics, 2010
- Photoelastic Stress Analysis in Screwed and Cemented Implant-Supported Dentures With External Hexagon ImplantsJournal of Craniofacial Surgery, 2010
- Preload and torque removal evaluation of three different abutment screws for single standing implant restorationsJournal of Applied Oral Science, 2008
- Influence of off-axis loading upon an anterior maxillary implant: a 3-dimensional finite element analysisJournal of Biomechanics, 2006
- Preloads Generated with Repeated Tightening in Three Types of Screws Used in Dental Implant AssembliesJournal of Prosthodontics, 2006
- An In Vitro Analysis of Implant Screw Torque Loss With External Hex and Internal Connection Implant SystemsImplant Dentistry, 2006
- Finite element analysis to determine implant preloadThe Journal of Prosthetic Dentistry, 2003
- Comparison of screw loosening, rotation, and deflection among three implant designsThe Journal of Prosthetic Dentistry, 1995