Automated extraction and amplification of DNA from whole blood using a robotic workstation and an integrated thermocycler
Authors:
- 1 October 2000
- journal article
- research article
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 32 (2) , 121-125
Abstract
Growing knowledge of the genetic basis of inheritable diseases has resulted in a rapidly increasing demand for DNA mutation analysis. Current methods are reliable and suitable for low‐throughput mutation analyses, but are unable to cope with the increasing demand for genetic analyses, necessitating the development of new, fully automated and reliable methods. We developed a semi‐automated method for DNA mutation analysis by integrating a thermocycler into a robotic pipetting workstation. DNA was extracted from 84 samples of 10 μl of EDTA‐treated whole blood using magnetic beads within 2 h. Directly after isolation, the DNA was automatically transferred to an integrated thermocycler for amplification. Our semi‐automated method proved to be reliable and robust, showing unambiguously interpretable PCR signals without occurrence of contamination. It is also faster than conventional manual methods. Only a brief manual intervention is required to remove and refit the seal of the PCR plate. This semi‐automated assay is a step forward in the development of fully automated assays for DNA mutation analysis.Keywords
This publication has 16 references indexed in Scilit:
- Multiplex detection of single-nucleotide variations using molecular beaconsGenetic Analysis: Biomolecular Engineering, 1999
- Identification of four novel mutations in severe methylenetetrahydrofolate reductase deficiencyEuropean Journal of Human Genetics, 1998
- Molecular beacons: a new approach for semiautomated mutation analysisClinical Chemistry, 1998
- Thermolabile Methylenetetrahydrofolate Reductase and Factor V Leiden in the Risk of Deep-Vein ThrombosisThrombosis and Haemostasis, 1998
- Multicolor molecular beacons for allele discriminationNature Biotechnology, 1998
- Genetic Typing by Capillary Electrophoresis with the Allelic Ladder as an Absolute StandardAnalytical Chemistry, 1996
- Molecular Beacons: Probes that Fluoresce upon HybridizationNature Biotechnology, 1996
- Separation of DNA sequencing fragments using an automated capillary electrophoresis instrumentElectrophoresis, 1996
- Mutated methylenetetrahydrofolate reductase as a risk factor for spina bifidaThe Lancet, 1995
- A candidate genetic risk factor for vascular disease: a common mutation in methylenetetrahydrofolate reductaseNature Genetics, 1995