Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation
- 16 September 2015
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 135 (12) , 1655-1662
Abstract
Background We sought to evaluate clinical and biomechanical outcomes of dual mini-fragment plate fixation for clavicle fractures. We hypothesized that this technique would produce an anatomical reduction with good clinical outcomes, be well tolerated by patients, and demonstrate equivalent biomechanics to single plating. Methods Dual mini-fragment plating was performed for 17 isolated, displaced midshaft clavicle fractures. Functional outcomes and complications were retrospectively reviewed. A sawbones model compared dual plating biomechanics to a (1) superior 3.5-mm locking reconstruction plate, or (2) antero-inferior 3.5-mm locking reconstruction plate. Results On biomechanical testing, with anterior loading, dual plating was significantly more rigid than single locked anterior-plating (p = 0.02) but less rigid than single locked superior-plating (p = 0.001). With superior loading, dual plating trended toward higher rigidity versus single locked superior-plating (p = 0.07) but was less rigid than single locked anterior-plating (p = 0.03). No statistically significant differences in axial loading (p = 0.27) or torsion (p = 0.23) were detected. Average patient follow-up was 16.1 months (12–38). Anatomic reduction was achieved and maintained through final healing (average 14.7 weeks). No patient underwent hardware removal. Average 1-year DASH score was 4.0 (completed in 88 %). Conclusions Displaced midshaft clavicle fractures can be effectively managed with dual mini-fragment plating. This technique results in high union rates and excellent clinical outcomes. Compared to single plating, dual plating is biomechanically equivalent in axial loading and torsion, yet offers better multi-planar bending stiffness despite the use of smaller plates. This technique may decrease the need for secondary surgery due to implant prominence and may aid in fracture reduction by buttressing butterfly fragments in two planes.Keywords
Funding Information
- Synthes Product-in-Kind Donation (NA)
This publication has 27 references indexed in Scilit:
- Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fracturesJournal of Orthopaedics and Traumatology, 2011
- Complications of clavicle fractures treated with intramedullary fixationJournal of Shoulder and Elbow Surgery, 2011
- Does delay matter? The restoration of objectively measured shoulder strength and patient-oriented outcome after immediate fixation versus delayed reconstruction of displaced midshaft fractures of the clavicleJournal of Shoulder and Elbow Surgery, 2007
- Deficits Following Nonoperative Treatment of Displaced Midshaft Clavicular FracturesJournal of Bone and Joint Surgery, 2006
- Midshaft Malunions of the ClavicleJournal of Bone and Joint Surgery, 2004
- Elastic stable intramedullary nailing of midclavicular fractures in athletesBritish Journal of Sports Medicine, 2003
- Treatment of Clavicular Aseptic NonunionThe Journal of Trauma: Injury, Infection, and Critical Care, 1998
- Closed treatment of displaced middle-third fractures of the clavicle gives poor resultsThe Journal of Bone and Joint Surgery. British volume, 1997
- Clavicular Nonunion and Malunion: Evaluation and Surgical ManagementJournal of the American Academy of Orthopaedic Surgeons, 1996
- NONUNION OF THE CLAVICLEJAMA, 1960