Human exposure to 2450 MHz CW energy at levels outside the IEEE C95.1 standard does not increase core temperature†
- 9 August 2001
- journal article
- research article
- Published by Wiley in Bioelectromagnetics
- Vol. 22 (6) , 429-439
Abstract
Permission was received from the Brooks AFB Institutional Review Board and the AF Surgeon General's Office to exceed the peak power density (PD = 35 mW/cm2) we had previously studied during partial body exposure of human volunteers at 2450 MHz. Two additional peak PD were tested (50 and 70 mW/cm2). The higher of these PD (normalized peak local SAR = 15.4 W/kg) is well outside the IEEE C95.1 guidelines for partial body exposure, as is the estimated whole body SAR ≈ 1.0 W/kg. Seven volunteers (four males, three females) were tested at each PD in three ambient temperatures (Ta = 24, 28, and 31°C) under our standard protocol (30 min baseline, 45 min RF exposure, 10 min baseline). The thermophysiological data (esophageal and six skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow) were combined with comparable data at PD = 0, 27, and 35 mW/cm2 from our 1999 study to generate response functions across PD. No change in esophageal temperature or metabolic heat production was recorded at any PD in any Ta. At PD = 70 mW/cm2, skin temperature on the upper back (irradiated directly) increased 4.0°C in Ta = 24°C, 2.6°C in Ta = 28°C, and 1.8°C in Ta = 31°C. These differences were primarily due to the increase in local sweat rate, which was greatest in Ta = 31°C. Also at PD = 70 mW/cm2, local skin blood flow on the back increased 65% over baseline levels in Ta = 31°C, but only 40% in Ta = 24°C. Although Ta becomes an important variable when RF exposure exceeds the C95.1 partial body exposure limits, vigorous heat loss responses of blood flow and sweating maintain thermal homeostasis efficiently. It is also clear that strong sensations of heat and thermal discomfort will motivate a timely retreat from a strong RF field, long before these physiological responses are exhausted. Bioelectromagnetics 22:429–439, 2001. Published 2001 Wiley‐Liss, Inc.Keywords
This publication has 13 references indexed in Scilit:
- HEATING AND PAIN SENSATION PRODUCED IN HUMAN SKIN BY MILLIMETER WAVESHealth Physics, 2000
- Physiological and Perceptual Responses of Human Volunteers during Whole-Body RF Exposure at 450 MHz1999
- Thermophysiological responses of human volunteers during controlled whole-body radio frequency exposure at 450 MHzBioelectromagnetics, 1998
- Outdoor measurement of SAR in a full‐sized human model exposed to 29.9 MHz in the near fieldBioelectromagnetics, 1989
- On the thermoregulatory consequences of NMR imagingMagnetic Resonance Imaging, 1986
- CIRCULATORY AND SWEATING RESPONSES DURING EXERCISE AND HEAT STRESS1983
- Auditory perception of radio-frequency electromagnetic fieldsThe Journal of the Acoustical Society of America, 1982
- A comparative study of human sensory thresholds: 2450‐MHz Microwaves vs far‐infrared radiationBioelectromagnetics, 1982
- Analyses of Electromagnetic Fields Induced in Biological Tissues by Thermographic Studies on Equivalent Phantom ModelsIEEE Transactions on Microwave Theory and Techniques, 1971
- Influence of Passive and Active Heating on the Temperature Regulation of ManActa Physiologica Scandinavica, 1965