Abstract
Background: This work used software-guided radiographic measurement to assess the effects of progressive lateral column lengthening (LCL) on restoring alignment in a novel cadaveric model of stage II-B flatfoot deformity. Methods: A stage II-B flatfoot was created in 8 cadaveric specimens by transecting the spring ligament complex, anterior deltoid, and interosseous talocalcaneal and cervical ligaments. Weightbearing computed tomographic (WBCT) scans were performed with specimens under 450 N of compressive load in the intact, flat, and 6-, 8-, and 10-mm lateral column–lengthening conditions. Custom software-guided radiographic measurements of the lateral talo–first metatarsal (Meary) angle, anteroposterior talo–first metatarsal angle, naviculocuneiform overlap, and 2 new measures (plantar fascia [PF] distance and angle) were recorded on digitally reconstructed radiographs. Four anonymized analysts performed measurements twice. Intra- and interobserver agreement was assessed using intraclass correlation coefficients (ICCs). Results: Six-millimeter LCL restored alignment closest to the intact foot in this new cadaveric model, whereas 10-mm lengthening tended toward overcorrection. The PF line displaced laterally in the flatfoot condition, and LCL restored the PF line to a location beneath the talonavicular joint. Interobserver agreement was excellent for PF distance (ICC = 0.99) and naviculocuboid overlap (ICC = 0.91), good for Meary angle (ICC = 0.81) and PF angle (ICC = 0.69), and acceptable for the talonavicular coverage angle (ICC = 0.65). Conclusion: In this stage II-B cadaveric flatfoot model, cervical ligament transection was essential to create deformity after the medial hindfoot ligaments were transected. Software-guided radiographic measurement proved reliable; standardized implementation should improve comparability between studies of flatfoot deformity. The novel PF distance performed most consistently (ICC = 0.99) and warrants further study. With this model, we found that a 6-mm LCL restored alignment closest to the intact foot, whereas 10-mm lengthening tended toward overcorrection. Clinical Relevance: Future joint-sparing flatfoot corrections may consider using a relatively small LCL combined with other bony and/or anatomic ligament/tendon reconstructions.Keywords
This publication has 32 references indexed in Scilit:
- Sensitivity of Plantar Pressure and Talonavicular Alignment to Lateral Column Lengthening in Flatfoot ReconstructionJournal of Bone and Joint Surgery, 2013
- Tripod IndexFoot & Ankle International, 2013
- Isolated Spring Ligament Failure as a Cause of Adult-Acquired Flatfoot DeformityFoot & Ankle International, 2013
- Reliability and Validity of Radiographic Measurements in Hindfoot Varus and ValgusJournal of Bone and Joint Surgery, 2010
- Plantar Pressures in Patients with and without Lateral Foot Pain After Lateral Column LengtheningJournal of Bone and Joint Surgery, 2010
- Acquired adult flat foot due to isolated plantar calcaneonavicular (spring) ligament insufficiency with a normal tibialis posterior tendonFoot and Ankle Surgery, 2008
- Posterior Tibial Tendon Rupture: A Refined Classification SystemFoot and Ankle Clinics, 2007
- Lateral Column Calcaneal Lengthening, Flexor Digitorum Longus Transfer, and Opening Wedge Medial Cuneiform Osteotomy for Flexible Flatfoot: A Biomechanical StudyFoot & Ankle International, 2007
- Lateral Column Lengthening by Calcaneal OsteotomyTechniques in Foot & Ankle Surgery, 2003
- Surgical Treatment of Stage I Posterior Tibial Tendon DysfunctionFoot & Ankle International, 1994