Methods for reverberation suppression utilizing dual frequency band imaging
- 1 September 2013
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (3) , 2313-2325
Abstract
Reverberations impair the contrast resolution of diagnostic ultrasound images. Tissue harmonic imaging is a common method to reduce these artifacts, but does not remove all reverberations. Dual frequency band imaging (DBI), utilizing a low frequency pulse which manipulates propagation of the high frequency imaging pulse, has been proposed earlier for reverberation suppression. This article adds two different methods for reverberation suppression with DBI: the delay corrected subtraction (DCS) and the first order content weighting (FOCW) method. Both methods utilize the propagation delay of the imaging pulse of two transmissions with alternating manipulation pressure to extract information about its depth of first scattering. FOCW further utilizes this information to estimate the content of first order scattering in the received signal. Initial evaluation is presented where both methods are applied to simulated and in vivo data. Both methods yield visual and measurable substantial improvement in image contrast. Comparing DCS with FOCW, DCS produces sharper images and retains more details while FOCW achieves best suppression levels and, thus, highest image contrast. The measured improvement in contrast ranges from 8 to 27 dB for DCS and from 4 dB up to the dynamic range for FOCW.Keywords
This publication has 25 references indexed in Scilit:
- Combination of tissue harmonic sonography, real-time spatial compound sonography and adaptive image processing technique for the detection of carotid plaques and intima-medial thicknessEuropean Journal of Radiology, 2009
- US ArtifactsRadioGraphics, 2009
- A new imaging technique based on the nonlinear properties of tissues2002
- Tissue harmonic imaging2002
- Nonlinear acoustics in diagnostic ultrasoundUltrasound in Medicine & Biology, 2002
- Artifacts and Pitfalls in Sonographic Imaging of the BreastAmerican Journal of Roentgenology, 2001
- Comparison of Tissue Harmonic Imaging with Conventional US in Abdominal DiseaseRadioGraphics, 2000
- Basic Physics and Imaging Characteristics of UltrasoundWorld Journal of Surgery, 2000
- Tissue harmonic imaging: Why does it work?Journal of the American Society of Echocardiography, 1998
- Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasoundThe Journal of the Acoustical Society of America, 1997