Diaphragm Ultrasonography as an Alternative to Whole-Body Plethysmography in Pulmonary Function Testing
Authors:
- Jonathan P. FuldJFJonathan P. Fuld
- Niall G. MacFarlaneNMNiall G. MacFarlane
Open Access
- 1 February 2006
- journal article
- research article
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 25 (2) , 225-232
Abstract
Objective. Whole‐body plethysmography is a common method of measuring pulmonary function. Although this technique provides a sensitive measure of pulmonary function, it can be problematic and unsuitable in some patients. The development of more accessible techniques would be beneficial. Methods. A prospective study was performed to validate diaphragm ultrasonography as an alternative to whole‐body plethysmography in patients referred for pulmonary function testing. Diaphragm movement and position were assessed by ultrasonography after standard pulmonary function testing using whole‐body plethysmography. Results. A wide range of lung function was observed. Standard lung volumes were as follows: total lung capacity, 5.57 ± 1.31 L, residual volume, 2.27 ± 0.56 L; and vital capacity, 3.30 ± 0.98 L (mean ± SD). The ratio of forced expiratory volume in 1 second to forced vital capacity was calculated as 0.69 ± 0.08. Ultrasonography showed that mean diaphragm excursion values were 11.1 ± 3.8 mm (2‐dimensional), 14.7 ± 4.1 mm during quiet breathing (M‐mode), and 14.8 ± 3.9 mm during a maximal sniff (M‐mode). The velocity of diaphragm movement rose sharply during the sniff maneuver from 15.2 ± 5.8 mm/s during quiet breathing to 104.0 ± 33.4 mm/s. Static 2‐dimensional measures of diaphragm position at the end of quiet inspiration or expiration correlated with standard measures of lung volume on plethysmography (eg, a correlation coefficient of 0.83 was obtained with end inspiration and vital capacity). All measures of diaphragm movement (whether by 2‐dimensional or M‐mode techniques) were poorly correlated with any lung volumes measured. Conclusions. These data suggest that dynamic measurements using diaphragm ultrasonography provide a relatively poor measure of pulmonary function in relation to whole‐body plethysmography.Keywords
This publication has 13 references indexed in Scilit:
- Physiological and radiological characterisation of patients diagnosed with chronic obstructive pulmonary disease in primary careThorax, 2000
- Sniff nasal inspiratory pressure in childrenPediatric Pulmonology, 2000
- Comparison of two new methods for the measurement of lung volumes with two standard methodsThorax, 1999
- Blunt traumatic rupture of the diaphragm: sonographic diagnosis.Journal of Ultrasound in Medicine, 1997
- Non-invasive quantification of diaphragm kinetics using m-mode sonographyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1997
- In vivo assessment of diaphragm contraction by ultrasound in normal subjects.Thorax, 1995
- Ultrasonic evaluation of movement of the diaphragm after acute cerebral infarction.Journal of Neurology, Neurosurgery & Psychiatry, 1995
- Ultrasound assessment of normal hemidiaphragmatic movement: relation to inspiratory volume.Thorax, 1994
- Technical report: Quantitative assessment of diaphragmatic movement — A reproducible method using ultrasoundClinical Radiology, 1992
- The Maximal Sniff in the Assessment of Diaphragm Function in ManClinical Science, 1985