Follow-up of 11–16 years after modular fixed-bearing TKA
Authors:
- 5 April 2008
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 33 (2) , 431-435
Abstract
To present representative data of long-term survivorship and clinical outcome for the PFC total knee arthroplasty (PFC-TKA). A consecutive series of 141 TKA was followed for a mean of 13 years (range, 11–16 years). Sixty-five knees were evaluated, 30 of these clinically and radiographically. Twenty-eight knees could only be assessed with the use of a questionnaire. Six patients were living in nursing homes. Fifty-four patients (65 knees) had died. Eleven had undergone a revision. One patient was considered lost to follow-up. With re-operation for any reason as the endpoint, the 10-year survival rate was 92% (n = 91 patients at risk), and the 14-year survival rate was 91% (n = 12). With aseptic loosening of the implant as the endpoint, the 10- and 14-year survival rates were 97%. The mean Knee Society and function scores were 76 and 48 points, respectively. In this multi-surgeon series modular fixed-bearing TKA had good clinical and radiographic results with excellent long-term survivorship.Keywords
This publication has 16 references indexed in Scilit:
- The Chitranjan Ranawat Award: Long-term Survivorship and Failure Modes of 1000 Cemented Condylar Total Knee ArthroplastiesClinical Orthopaedics and Related Research, 2006
- Whatʼs New in Adult Reconstructive Knee SurgeryJournal of Bone and Joint Surgery, 2006
- A response to issues raised in a recent paper concerning the Oxford knee scoreThe Knee, 2006
- Successful Biologic Fixation With Mobile-Bearing Total Knee ArthroplastyThe Journal of Arthroplasty, 2005
- Modular Fixed-Bearing Total Knee Arthroplasty with Retention of the Posterior Cruciate LigamentJournal of Bone and Joint Surgery, 2005
- FACTORS AFFECTING THE DURABILITY OF PRIMARY TOTAL KNEE PROSTHESESJournal of Bone and Joint Surgery, 2003
- Long-Term Followup After Mobile-Bearing Total Knee ReplacementClinical Orthopaedics and Related Research, 2002
- Total knee arthroplasty with the PFC systemThe Journal of Bone and Joint Surgery. British volume, 1998
- Three-dimensional polyethylene wear of a press-fit titanium prosthesisThe Journal of Arthroplasty, 1997
- Long-Term Results of the Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1993