Individually tailored contrast enhancement in CT pulmonary angiography
- 1 May 2016
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1061) , 20150850
Abstract
Purpose:The purpose was to evaluate individually shaped contrast media (CM) delivery in CT pulmonary angiography (CTPA) for suspected pulmonary embolism.Materials and Methods:100 consecutive emergency patients with clinical suspicion for pulmonary embolism were evaluated. High-pitch CTPA was performed on a 2nd generation dual-source CT using the following parameters: 100kV, 200-250mAsref, rot.time 0.28s, 128x0.6mm col., image reconstruction 1.0/0.8mm (B30f). Group 1 (n=50) then received a fixed CM bolus (300mgI/ml, volume=90ml, flow rate=6ml/s); group 2 (n=50) received a body weight adapted CM bolus determined by dedicated contrast injection software. For analysis, groups were further subdivided into low (40-75kg) and high (76-117kg) weight groups. Technical image quality was graded using a four-point Likert scale (1=non-diagnostic; 2=diagnostic; 3=good and 4=excellent image quality) at the level of the pulmonary trunk and pulmonary arteries. Objective image quality analysis was done measuring contrast en...Keywords
This publication has 43 references indexed in Scilit:
- CT angiography of intracranial arterial vessels: impact of tube voltage and contrast media concentration on image qualityActa Radiologica, 2012
- The Frequency of Insufficient Contrast Enhancement of the Pulmonary Artery in Routine Contrast-enhanced Chest CT and Its Improvement With an Increased Injection RateJournal of Thoracic Imaging, 2011
- Safety of ruling out acute pulmonary embolism by normal computed tomography pulmonary angiography in patients with an indication for computed tomography: systematic review and meta‐analysisJournal of Thrombosis and Haemostasis, 2009
- Cost reduction in abdominal CT by weight-adjusted doseEuropean Journal of Radiology, 2009
- Strategies for Reducing Radiation Dose in CTRadiologic Clinics of North America, 2009
- The Role of Multidetector Computed Tomography Angiography for the Diagnosis of Pulmonary EmbolismSeminars in Nuclear Medicine, 2008
- Contrast Injection Protocols for Coronary Computed Tomography Angiography Using a 64-Detector Scanner: Comparison Between Patient Weight-Adjusted- and Fixed Iodine-Dose ProtocolsInvestigative Radiology, 2008
- No Increased Risk for Contrast-Induced Nephropathy after Multiple CT Perfusion Studies of the Brain with a Nonionic, Dimeric, Iso-Osmolal Contrast MediumAmerican Journal of Neuroradiology, 2008
- Effect of X-ray Tube Parameters, Iodine Concentration, and Patient Size on Image Quality in Pulmonary Computed Tomography Angiography: A Chest-Phantom-StudyInvestigative Radiology, 2008
- Venous thromboembolism (VTE) in EuropeThrombosis and Haemostasis, 2007