Implementation of the structural SIMilarity (SSIM) index as a quantitative evaluation tool for dose distribution error detection
- 4 January 2020
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 47 (4) , 1907-1919
Abstract
Purpose: To apply an imaging metric of the structural SIMilarity (SSIM) index to the radiotherapy dose verification field and evaluate its capability to reveal the different types of errors between two dose distributions.Method: The SSIM index consists of three sub‐indices: luminance, contrast, and structure. Given two images, luminance analysis compares the local mean result, contrast analysis compares the local standard deviation, and the structure index represents the local Pearson correlation. Three test error patterns (absolute dose error, dose gradient error, and dose structure error) were designed to characterize the response of SSIM and its sub‐indices and establish the correlation between the indices and different dose error types. After establishing the correlation, four radiotherapy plans (one MLC picket‐fence test plan, one brain stereotactic radiotherapy plan, and two head‐and‐neck plans) were tested by computing each index and compared with the gamma analysis results to determine their similarities and differences.Results: Among the three test error patterns, the luminance index decreased from 1 to 0.1 when the absolute dose agreement fell from 100% to 5%, the contrast index decreased from 1 to 0.36 when the dose gradient agreement fell from 100% to 10%, and the structure index decreased from 1 to 0.23 when the periodical dose pattern shifted (leading to a lower correlation). Thus, the luminance, contrast and structure index can detect the absolute dose error, gradient discrepancy, and dose structure error, respectively. For the four clinical cases, the sub‐indices can reveal the type of error when gamma analysis only provided limited information.Conclusions: The correlation between the subcomponents of the SSIM index and the error types of the dose distribution were established. The SSIM index provides additional error information compared to that provided by gamma analysis.Keywords
This publication has 22 references indexed in Scilit:
- Developing new extension of GafChromic RTQA2 film to patient quality assurance field using a plan-based calibration methodPhysics in Medicine & Biology, 2015
- A study on investigating the delivery parameter error effect on the variation of patient quality assurance during RapidArc treatmentMedical Physics, 2013
- 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetryRadiotherapy and Oncology, 2010
- Patient‐specific quality assurance method for VMAT treatment deliveryMedical Physics, 2009
- Comparison of two commercial detector arrays for IMRT quality assuranceJournal of Applied Clinical Medical Physics, 2009
- Quality Assurance of Intensity-Modulated Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Characterization and use of EBT radiochromic film for IMRT dose verificationMedical Physics, 2006
- Error in the delivery of radiation therapy: Results of a quality assurance reviewInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Quality assurance in radiotherapy: evaluation of errors and incidents recorded over a 10 year periodRadiotherapy and Oncology, 2005
- Verification of dynamic and segmental IMRT delivery by dynamic log file analysisJournal of Applied Clinical Medical Physics, 2002