A Bayesian approach to solve proton stopping powers from noisy multi‐energy CT data
- 4 September 2017
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 44 (10) , 5293-5302
Abstract
Purpose: To propose a new formalism allowing the characterization of human tissues from multienergy computed tomography (MECT) data affected by noise and to evaluate its performance in estimating proton stopping powers (SPR).Methods: A recently published formalism based on principal component analysis called eigentissue decomposition (ETD) is adapted to the context of noise using a Bayesian estimator. The method, named Bayesian ETD, uses the maximum a posteriori fractions of eigentissues in each voxel to determine physical parameters relevant for proton beam dose calculation. Simulated dual‐energy computed tomography (DECT) data are used to evaluate the performance of the proposed method to estimate SPR and to compare it to the initially proposed maximum‐likelihood ETD and to a state‐of‐the‐art ρe − Z formalism. To test the robustness of each method towards clinical reality, three different levels of noise are implemented, as well as variations in elemental composition and density of reference tissues. The impact of using more than two energy bins to determine SPR is also investigated by simulating MECT data using two to five energy bins. Finally, the impact of using MECT over DECT for range prediction is evaluated using a probabilistic model.Results: For simulated DECT data of reference tissues, the Bayesian ETD approach systematically gives lower root‐mean‐square (RMS) errors with negligible bias. For a medium level of noise, the RMS errors on SPR are found to be 2.78%, 2.76% and 1.53% for ρe − Z, maximum‐likelihood ETD, and Bayesian ETD, respectively. When variations are introduced to the elemental composition and density, all implemented methods give similar performances at low noise. However, for a medium noise level, the proposed Bayesian method outperforms the two others with a RMS error of 1.94%, compared to 2.79% and 2.78% for ρe − Z and maximum‐likelihood ETD, respectively. When more than two energy spectra are used, the Bayesian ETD is able to reduce RMS error on SPR using up to five energy bins. In terms of range prediction, Bayesian ETD with four energy bins in realistic conditions reduces proton beam range uncertainties by a factor of up to 1.5 compared to ρe − Z.Conclusion: The Bayesian ETD is shown to be more robust against noise than similar methods and a promising approach to extract SPR from noisy DECT data. In the advent of commercially available multi‐energy CT or photon‐counting CT scanners, the Bayesian ETD is expected to allow extracting more information and improve the precision of proton therapy beyond DECT.Keywords
Funding Information
- Ministère de la santé et des services sociaux (MSSS) du Québec
This publication has 38 references indexed in Scilit:
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- XCOM intrinsic dimensionality for low-Z elements at diagnostic energiesMedical Physics, 2012
- Extracting atomic numbers and electron densities from a dual source dual energy CT scanner: Experiments and a simulation modelRadiotherapy and Oncology, 2011
- The impact of uncertainties in the CT conversion algorithm when predicting proton beam ranges in patients from dose and PET-activity distributionsPhysics in Medicine & Biology, 2010
- Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissuesPhysics in Medicine & Biology, 2010
- Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculationsPhysics in Medicine & Biology, 2008
- On the influence of noise correlations in measurement data on basis image noise in dual‐energylike x‐ray imagingMedical Physics, 2007
- A Brief Survey of Bandwidth Selection for Density EstimationJournal of the American Statistical Association, 1996
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996
- Average soft-tissue and bone models for use in radiation dosimetryBritish Journal of Radiology, 1987