Abstract
A new exhaust aerosol model CFD-TUTEAM (Tampere University of Technology Exhaust Aerosol Model for Computational Fluid Dynamics) was developed. The model can be used to simulate particle formation and evolution in diesel exhaust. The model has an Eulerian sub-model that provides spatial information within the computational domain, and a computationally less expensive Lagrangian sub-model that can be used to examine particle formation in a high temporal resolution. Particle formation in a laboratory sampling system that includes a porous tube type diluter and an aging chamber was modeled with CFD-TUTEAM. The simulation results imply that over 99% of new particles are formed in the aging chamber region, because nucleation rate remains at high level in the aging chamber due to low dilution ratio and low nucleation exponents. The nucleation exponents for sulfuric acid in sulfuric acid-water nucleation ranging from 0.25 to 1 appeared to fit best with measurement data, which are the same values as the slopes of volatile nucleation mode number concentration vs. raw exhaust sulfuric acid concentration obtained from the measurement data. These nucleation exponents are very low compared to the nucleation exponents obtained from the classical nucleation theory of binary sulfuric acid-water nucleation. The values of nucleation exponent lower than unity suggest that other compounds, such as hydrocarbons, might have a significant role in the nucleation process.
All Related Versions
Funding Information
  • Maj ja Tor Nesslingin Säätiö (2014452)
  • Tekes (TREAM)

This publication has 60 references indexed in Scilit: