Chip-Based Quantitative Capillary Electrophoresis/Mass Spectrometry Determination of Drugs in Human Plasma
Authors:
- 15 February 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (7) , 1432-1439
Abstract
A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the on-chip separation and coupled electrospray detection of selected small drug molecule compounds. These studies include the quantitative determination of carnitine and acetylcarnitine in analytical standard solutions as well as imipramine and desipramine in fortified human plasma samples. A clinical human plasma sample was also analyzed following the normal administration of desipramine to a volunteer, and the parent drug was determined using the described chip-based CE/MS technique. In each instance, stable isotope-incorporated internal standards were used. The chip-based CE system was microfabricated from glass and coupled to a micro ion spray device constructed in-house. The atmospheric pressure ionization system employed in this work was a PE Sciex API III tandem triple quadrupole system operated in the selected ion monitoring (SIM) mode. The results from the work reported here demonstrate the feasibility for carrying out rapid (30 s) chip-based quantitative CE/MS determinations of samples containing small-molecule compounds. Using SIM CE/MS techniques, the described API III quadrupole system provided acceptable ion current electropherograms from subpicomole levels of the targeted compounds loaded onto the chip. The corresponding electropherograms for the standard solution of carnitines at the 1−500 μg/mL level were obtained via SIM CE/MS techniques (R2 > 0.99). In addition, analyses of fortified samples of imipramine desipramine were measured relative to their corresponding d3 internal standards to obtain calibration curves ranging from 5 to 500 μg/mL in human plasma (R2 > 0.99). The intra-assay precision ranged from 4.1 to 7.3% RSD. The intra-assay accuracy ranged from 94.0 to 104%. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric determination in applications for bioanalytical measurements for these important compounds in synthetic mixtures and human plasma extracts.Keywords
This publication has 26 references indexed in Scilit:
- Microfluidic Devices Connected to Fused-Silica Capillaries with Minimal Dead VolumeAnalytical Chemistry, 1999
- Microchip Structures for Submillisecond ElectrophoresisAnalytical Chemistry, 1998
- Generating Electrospray from Microchip Devices Using Electroosmotic PumpingAnalytical Chemistry, 1997
- Effect of Electrical Double-Layer Overlap on the Electroosmotic Flow in Packed-Capillary ColumnsAnalytical Chemistry, 1997
- Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis DeviceAnalytical Chemistry, 1996
- Microchip Electrophoretic Immunoassay for Serum CortisolAnalytical Chemistry, 1996
- Microchip electrophoresis with sample stackingElectrophoresis, 1995
- Electroosmotic Pumping and Valveless Control of Fluid Flow within a Manifold of Capillaries on a Glass ChipAnalytical Chemistry, 1994
- Planar glass chips for capillary electrophoresis: repetitive sample injection, quantitation, and separation efficiencyAnalytical Chemistry, 1993
- Rapid signal processing techniques for Fourier transform infrared remote sensingTrAC Trends in Analytical Chemistry, 1991