Time Out! Is Timepiece Variability a Factor in Critical Care?
- 1 March 2005
- journal article
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 14 (2) , 113-120
Abstract
• Background Accurate documentation of time is essential in critical care for treatments, interventions, research, and medicolegal and quality improvement activities. • Objectives To assess use of timepieces in critical care and to determine practical methods for improving their accuracy. • Methods Providers were surveyed to identify timepieces used during routine and emergency care. Times displayed on standard unit and personal timepieces were compared with coordinated universal time. Four models of atomic clocks were assessed for drift for 6 weeks and for resynchronization for 1 week. Bedside monitors were manually synchronized to coordinated universal time and were assessed for drift. • Results Survey response was 78% (149/190). Nurses (n = 93), physicians (n = 32), and respiratory therapists (n = 24) use wall clocks (50%) and personal timepieces (46%) most frequently during emergencies. The difference from coordinated universal time was a median of −4 minutes (range, −5 minutes to +2 min) for wall clocks, −2.5 minutes (−90 minutes to −1 minute) for monitors, and 0 minutes (−22 minutes to +12 minutes) for personal timepieces. Kruskal-Wallis testing indicated significant variations for all classes of timepieces (P<.001) and for personal timepieces grouped by discipline (P=.02). Atomic clocks were accurate to 30 seconds of coordinated universal time for 6 weeks when manually set but could not be synchronized by radiofrequency signal. Drift of bedside monitors was 1 minute. • Conclusions Timepieces used in critical care are highly variable and inaccurate. Manually synchronizing timepieces to coordinated universal time improved accuracy for several weeks, but the feasibility of synchronizing all timepieces is undetermined.Keywords
This publication has 7 references indexed in Scilit:
- As Time Goes byScottish Medical Journal, 2002
- Synchronization of Timepieces to the Atomic Clock in an Urban Emergency Medical Services SystemAnnals of Emergency Medicine, 1998
- Does anybody really know what time it is? Does anybody really care?Annals of Emergency Medicine, 1994
- The most neglected tool in EMS: The clockAnnals of Emergency Medicine, 1993
- Prospective validation of a new model for evaluating emergency medical services systems by in-field observation of specific time intervals in prehospital careAnnals of Emergency Medicine, 1993
- Recommended guidelines for uniform reporting of data from out-of-hospital cardiac arrest: the Utstein Style. A statement for health professionals from a task force of the American Heart Association, the European Resuscitation Council, the Heart and Stroke Foundation of Canada, and the Australian Resuscitation Council.Circulation, 1991
- Outcome of CPR in a large metropolitan area — where are the survivors?Annals of Emergency Medicine, 1991