Can the use of an inclinometer improve acetabular cup inclination in total hip arthroplasty? A review of the literature
Open Access
- 4 August 2020
- journal article
- review article
- Published by SAGE Publications in HIP International
- Vol. 31 (5) , 609-617
Abstract
Introduction: The angle of acetabular (cup) radiographic inclination is an important measurement in total hip arthroplasty (THA) procedures. Abnormal radiographic inclination is associated with dislocation, edge loading and higher failure rates. Consistently achieving a satisfactory radiographic inclination remains a challenge. Inclinometers have been increasingly used over the last decade. This paper reviews the literature to determine whether using an inclinometer improves the accuracy of acetabular cup inclination in THA. Methods: A systematic literature search was performed. The following search terms were used: (‘hip’ OR ‘hip replacement’ OR ‘hip arthroplasty’ OR ‘primary hip replacement’ OR ‘THR’ OR ‘THA’ OR ’Acetabular cup Inclination’) AND (‘Inclinometer’). Titles and abstracts were screened for relevance. Both radiographic and operative inclination comparisons were included. Results: 7 studies met the inclusion criteria. 2 were randomised control trials with level I evidence, and the remaining studies were cohort studies with level III/IV evidence. 5 were clinical and 2 experimental. In total there were 16 cohorts: 7 using an inclinometer, 6 freehand, and 3 using MAG techniques. All studies comparing radiographic inclination and 1 of 2 studies comparing operative inclination showed an improvement in the attainment of the optimal inclination. Similarly, the use of an inclinometer showed a reduction in the number of outliers when compared to MAG and freehand techniques. Discussion: This review demonstrates that using an inclinometer improved the surgeon’s ability to achieve their intended inclination (both operative and radiographic) and reduced the incidence of positioning outside the safe-zone. However, only 2 of the studies were randomised control trials and these resulted in opposing conclusions. Therefore, further studies looking at the use of inclinometers would prove useful in understanding their true benefit.Keywords
Funding Information
- National Institute for Health Research
This publication has 60 references indexed in Scilit:
- Causes of Failure of Ceramic-on-Ceramic and Metal-on-Metal Hip ArthroplastiesClinical Orthopaedics and Related Research, 2012
- Should the Acetabular Cup be Medialised in Total Hip Arthroplasty?HIP International, 2011
- The John Charnley Award: Risk Factors for Cup Malpositioning: Quality Improvement Through a Joint Registry at a Tertiary HospitalClinical Orthopaedics and Related Research, 2011
- Acetabular Polyethylene Wear and Acetabular Inclination and Femoral OffsetClinical Orthopaedics and Related Research, 2009
- Combined Anteversion Technique for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2009
- The influence of the centre of rotation on implant survival using a modular stem hip prosthesisInternational Orthopaedics, 2008
- Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasiaInternational Orthopaedics, 2008
- Accuracy and potential pitfalls of fluoroscopy-guided acetabular cup placementComputer Aided Surgery, 2005
- Morphologic Features of the Acetabulum and FemurClinical Orthopaedics and Related Research, 2001
- Wear Is a Function of Use, Not TimeClinical Orthopaedics and Related Research, 2000