Comparison of TruView EVO2 with Miller laryngoscope in paediatric patients
Authors:
- Mehmet Turan InalMIMehmet Turan Inal
- Dilek MemisDMDilek Memis
- Murat KargiMKMurat Kargi
- Zumral OktayZOZumral Oktay
- Necdet SutNSNecdet Sut
- 1 November 2010
- journal article
- research article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 27 (11) , 950-954
Abstract
Except for neonates and specific malformations in children, management of the paediatric airway is not a major problem for the anaesthetist. Miller laryngoscope was traditionally used for paediatric intubation. The TruView EVO2 system is a recently introduced device with a unique blade that provides a wide and magnified laryngeal view. To assess the value of the TruView EVO2 laryngoscope with that of Miller laryngoscope in paediatric patients. Prospective analysis. Fifty 2-8-year paediatric patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a Miller (Group M, n = 25) and TruView EVO2 laryngoscope (Group T, n = 25). Preoperative airway evaluation was performed by using the Mallampati scores. The Intubation Difficulty Scale (IDS), the duration of the tracheal intubation procedure, the rate of successful placement of the endotracheal tube in the trachea, the view of the glottis according to the Cormack and Lehane grading criteria, number of intubation attempts, mean arterial pressure (MAP) and heart rate (HR) before and after intubation, lowest peripheric oxygen saturation during intubation attempts and all complications (minor laseration, dental or other airway trauma) were all recorded. Preoperative Mallampati scores and the IDS scores were similar between the Miller and TruView EVO2 laryngoscope. The average time for laryngoscopy was 6.36 ± 0.99 s in group M and 13.8 ± 7.99 s in group T (P < 0.001). The TruView EVO2 laryngoscope improved the Cormack and Lehane glottic view compared with the Miller laryngoscope. The HR change (difference before and after) in group M was significantly lower than that in group T (P < 0.001). However, the MAP change was similar between groups. The lowest peripheric oxygen saturation during intubation attempts was different between groups, 99.4 ± 0.57% in group M and 97.6 ± 2.41% in group T (P < 0.001). The results suggest that when compared with the Miller laryngoscope, the TruView EVO2 laryngoscope appears to improve the view of the larynx but requires a longer time for tracheal intubation. The IDS scores were similar; thus, the TruView EVO2 laryngoscope can be a good alternative to traditionally used Miller laryngoscope.Keywords
This publication has 11 references indexed in Scilit:
- A comparison of Truview infant EVO2 laryngoscope with the Miller blade in neonates and infantsPediatric Anesthesia, 2009
- A left paraglossal approach for oral intubation in children scheduled for bilateral orofacial cleft reconstruction surgery – a prospective observational studyPediatric Anesthesia, 2009
- Paediatric airway management: basic aspectsActa Anaesthesiologica Scandinavica, 2008
- Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilizationBritish Journal of Anaesthesia, 2008
- A comparison of the Truview ® blade with the Macintosh blade in adult patientsAnaesthesia, 2007
- Randomized controlled trial comparing the laryngeal tube and the laryngeal mask in pediatric patientsPediatric Anesthesia, 2005
- The Intubation Difficulty Scale (IDS)Anesthesiology, 1997
- Adverse Respiratory Events in Anesthesia: A Closed Claims AnalysisAnesthesiology, 1990
- A clinical sign to predict difficult tracheal intubation; a prospective studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985
- Difficult tracheal intubation in obstetricsAnaesthesia, 1984