Abstract
A single resonance-type spin-torque microwave diode (STMD) can be used as a quadratic detector to determine the frequency f of an external microwave signal when the power P rf of this signal is known. However, unless the signal's frequency f exactly coincides with the detector's resonance frequency f res , there exists a finite frequency determination error Δf. In this letter, we show theoretically and experimentally that if a pair of independent STMDs with different resonance frequencies connected in parallel is used for the signal frequency determination, knowledge of the signal power is not necessary, and the frequency determination error can be substantially reduced to Δf ≈ 30 MHz at the frequency of f ≈ 5.0 GHz.
Funding Information
  • Ministry of Education and Science of Ukraine (19BF05201)
  • Oakland University Foundation
  • Defense Threat Reduction Agency (HDTRA1-16-1-0025)
  • National Academy of Sciences of Ukraine (1F)
  • North Atlantic Treaty Organization (SPS.MYP grant No. G5792)
  • Air Force Office of Scientific Research (MURI Grant No. FA9550- 19-1-0307)
  • National Science Foundation (DMR-1610146, ECCS-1708885, EFMA-1641989)
  • Army Research Office (W911NF-16-1-0472)

This publication has 26 references indexed in Scilit: