Development and characterization of the Hydra: a novel multi-headed, single optical channel scintillation detector
- 21 July 2025
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (15) , 15NT01
Abstract
Objective. Plastic scintillation detectors (PSDs) possess many properties (small size, water-equivalence, real-time reading) that make them well suited for dosimetric applications in radiotherapy. Multi-point PSDs (mPSDs) further enhance capabilities of PSDs, incorporating multiple detection points cascaded within a single collecting optical fiber in order to provide more spatial information about the radiation field. The goal of this study was to develop and characterize a novel mPSD design, called Hydra, that possesses multiple optical fiber heads connected to a single optical fiber. Each head tip includes a single scintillating element, allowing to measure the dose simultaneously at three independent locations in space. Approach. The Hydra design consists of three Medscint proprietary scintillators with emission peaks at 434, 428 and 530 nm. The optical fibers of each head and the collecting fiber are made of PMMA (ESKA GH-4001, Mitsubitshi Chemical Co., Tokyo, Japan). The Hydra was used to measure output factors, dose profiles and percent-depth-dose (PDD) curves in water under a 6 MV photon beam, individually for each head as well as with all three heads in the irradiation beam. Main results. The deviation on output factors, when all three heads are in the irradiation field, remains within ±1.1% as compared to when only 1 head is in the irradiation field. For the profile and PDD curves, the deviation with the reference curves remains within ±2% in the high-dose and low-gradient regions. Significance. The Hydra offers a good control on the uniformity of light intensity coming from each scintillator, a freedom to measure independently in a non-contiguous space, and an easier and more accurate calibration procedure compared to previous mPSD designs. These advantages open the door to new possibilities for multi-point dosimetry applications.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 23 references indexed in Scilit:
- Field output correction factors using a scintillation detectorMedical Physics, 2025
- Radioluminescence-based fibre-optic dosimeters in radiotherapy: a reviewRadiation Measurements, 2024
- Characteristics of a plastic scintillation detector in photon beam dosimetryJournal of Applied Clinical Medical Physics, 2023
- Technical note: Characterization and practical applications of a novel plastic scintillator for online dosimetry for an ultrahigh dose rate (FLASH)Medical Physics, 2022
- Report of AAPM Task Group 155: Megavoltage photon beam dosimetry in small fields and non‐equilibrium conditionsMedical Physics, 2021
- Feasibility of improving patient’s safety with in vivo dose tracking in intracavitary and interstitial HDR brachytherapyBrachytherapy, 2021
- Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapyMedical Physics, 2019
- A mathematical formalism for hyperspectral, multipoint plastic scintillation detectorsPhysics in Medicine & Biology, 2012
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerationsPhysics in Medicine & Biology, 1992
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurementsPhysics in Medicine & Biology, 1992