Fast spin-echo MR imaging of the pediatric brain
Authors:
- 1 April 1996
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 26 (4) , 259-264
Abstract
On a 1.5-T MR unit conventional spin-echo (CSE) and fast spin-echo (FSE) images were obtained in 70 consecutive children ranging from 4 days to 13 years in age. They suffered from developmental retardation, neurodegenerative, ischemic or inflammatory diseases. In our prospective study artifacts, lesion conspicuity and general impression were compared between double-echo (proton density- and T2-weighted) CSE and single-echo (T2-weighted) FSE images. Phase artifacts from flowing blood were seen rarely on the FSE images, while motion artifacts appeared more frequently. Assessment of myelination in 43 children with unfinished myelination revealed no difference between FSE and CSE. The lesion conspicuity in 20 children with focal abnormalities compared favorably between FSE and CSE. There was no diagnostically relevant difference between FSE and CSE, although in FSE spin density images were missing. FSE sequences can be used in MR imaging of the pediatric brain without disadvantage and with a time reduction of 67-75%.Keywords
This publication has 18 references indexed in Scilit:
- MR detection of white matter disease of the brain in patients with HIV infection: fast spin-echo vs conventional spin-echo pulse sequences.American Journal of Roentgenology, 1994
- Comparison of T2‐weighted spin‐echo and fast spin‐echo techniques in the evaluation of myelinationJournal of Magnetic Resonance Imaging, 1994
- Fast Spin-Echo Imaging of Intracranial NeoplasmsJournal of Computer Assisted Tomography, 1993
- Turbo(Fast)-Spinecho bei 0,5 T: Einfluß der Echodistanz und Echozahl auf den BildkontrastRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1993
- Why fat is bright in rare and fast spin‐echo imagingJournal of Magnetic Resonance Imaging, 1992
- Fast spin-echo MR imaging of the brain and spine: current concepts.American Journal of Roentgenology, 1992
- Practical choices of fast spin echo pulse sequence parameters: clinically useful proton density and T2-weighted contrastsNeuroradiology, 1992
- Signal-to-Noise and Contrast in Fast Spin Echo (FSE) and Inversion Recovery FSE ImagingJournal of Computer Assisted Tomography, 1992
- Comparing the FAISE method with conventional dual‐echo sequencesJournal of Magnetic Resonance Imaging, 1991
- Contrast manipulation and artifact assessment of 2D and 3D RARE sequencesMagnetic Resonance Imaging, 1990