Comparison of Long-Term Microscopic and Endoscopic Audiologic Results After Total Ossicular Replacement Prosthesis Surgery

Authors:

Abstract
Objective: To compare short-term and long-term outcomes after transcanal endoscope-assisted with microscope-assisted ossiculoplasty using the Fisch titanium total prosthesis (FTTP). Study Design: Retrospective chart review. Setting: Tertiary referral center. Patients: Pediatric ( 0.05). Three months postoperative endoscopic air conduction PTA0.5-2kHz was 37.6 ± 17.4 dB (14.5 dB improvement) and 44.6 ± 19.9 dB (7.6 dB improvement) in the microscopic group (p > 0.05). Three months postoperative endoscopic PTA0.5-2kHz ABG was 26.8 ± 16.6 dB and 28.4 ± 14.7 dB in the microscopic group (p > 0.05). Latest follow-up endoscopic air conduction PTA0.5-2kHz audiogram (mean follow-up, 20.6 ± 10.4 mo) was 36.1 ± 18.2 dB (16.0 dB improvement) and 40.1 ± 16.8 dB (12.1 dB improvement) in the microscopic group (mean follow-up, 19.9 ± 10.3 mo)(p > 0.05). For endoscopic air conduction PTA0.5-2kHz, between the 3 months and latest follow-up audiogram, 25.0% showed improvement, 50.0% remained stable, and 25.0% deteriorated. In the microscopic group, 26.7% improved, 46.6% remained stable, and 26.7% deteriorated (p > 0.05). Conclusion: Our study shows that hearing results with the Fisch titanium total prosthesis are in line with literature. Endoscope-assisted total ossiculoplasty proves to be a suitable technique with comparable results to the microscopic approach.

This publication has 26 references indexed in Scilit: