New multimodal data obtained in-vivo from a single ultra-miniature transducer
- 3 July 2015
- journal article
- Published by Springer Nature in Biomedical Microdevices
- Vol. 17 (4)
Abstract
Recent advances in multimodal sensing technology and sensor miniaturization technologies are paving the way for a new era in physiological measurement. Traditional approaches have integrated several transducers on a single silicon chip or packaged several sensing elements within a biocompatible catheter. Thermal and electrical cross-talk between sensors, time-lag between parallel measurements, lower yields associated with the increased complexity, and restrictions on the minimum size are challenges presented by these approaches. We present an alternative method which enables simultaneous measurement of temperature, pressure and heart rate to be obtained from a single ultra-miniature solid-state transducer. For the first time multimodal data were obtained from the sensor located within the abdominal aortas of five rats. The catheter-tip sensor interfaces with a fully implanted and inductively powered telemetry device capable of operating for the lifetime of the animal. Results of this study demonstrate good agreement between the core-temperature measurement from the catheter-tip sensor and the reference sensor with mean difference between the two sensors of 0.03 °C ± 0.02 °C (n = 5, 7 days). Real-time data obtained in the undisturbed rat, revealed fluctuations associated with the rest-activity cycle, in temperature, mean arterial pressure and heart rate. The stress response was shown to elicit an elevation in the core temperature of 1.5 °C. This was heralded by an elevation in mean arterial pressure of 35 mmHg and heart rate of 160 bpm. Obtaining multiple parameters from a single transducer goes a considerable way towards overcoming challenges of the prior art.Keywords
This publication has 25 references indexed in Scilit:
- Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensorsBiomedical Microdevices, 2011
- Report of a Consensus Meeting on Human Brain Temperature After Severe Traumatic Brain Injury: Its Measurement and Management During PyrexiaFrontiers in Neurology, 2010
- Quantifying the instability of core temperature in rodentsJournal of Thermal Biology, 2009
- A flexible polymer tube lab-chip integrated with microsensors for smart microcatheterBiomedical Microdevices, 2008
- VI. Indications for Intracranial Pressure MonitoringJournal of Neurotrauma, 2007
- Telemetered recording of blood pressure and heart rate in different strains of rats during chronic social stressPhysiology & Behavior, 1995
- Effect of cold exposure on organ temperatures in Wistar and Zuker fa/fa ratJournal of Thermal Biology, 1992
- Effect of food deprivation and refeeding on rat organ temperaturesArchives Internationales de Physiologie, de Biochimie et de Biophysique, 1992
- Piezoresistance effect of siliconSensors and Actuators A: Physical, 1991
- Learned anticipatory rise in body temperature due to handlingPhysiology & Behavior, 1986