Non-invasive acquisition of vital data in anesthetized rats using laser and radar application
Authors:
- 11 September 2024
- journal article
- research article
- Published by SAGE Publications in Laboratory Animals
- Vol. 58 (6) , 591-601
Abstract
The aim of this study was to verify the possibility of obtaining vital sign information using a laser and radar sensor in a manner that is non-invasive and painless for test animals. A dataset was obtained from respiratory movement of anaesthetized male F344 rats, signals of laser and radar sensors were recorded simultaneously with vital data acquired with an integrated multiple-channel intraoperative monitor. In addition, respiratory movements were also video recorded, and used as reference data of respiration rate (RR; ref-RR). Reference data for heart rate (HR; ref-HR) were obtained from the R wave of electrocardiogram data for each epoch. Signals recorded from the radar sensor (I- and Q-signals) were input to a computer, and HR (radar-HR) and RR (radar-RR) were estimated using the frequency analysis method. Among the six positions where respiratory movements were measured by the laser sensor, the number of peak counts matched the visual counts of respiratory movements in the video records. The respiratory movements were significantly the greatest over the most caudal rib in the dorsal ( p < 0.001). The average radar-RR and ref-RR values showed correspondence (ref-RR, 69 ± 6.2 breaths/min; radar-RR, 68 ± 5.7 breaths/min ( p = 0.04–1.00); equivalence ratio, 86%). The radar-HR data showed slight variability; however, there was 80% homology compared with the ref-HR values (ref-HR, 336 ± 19.6 beats/min; radar-HR, 348 ± 34.1 ( p = 0.10–0.95)). Although comparison of the data under noradrenaline administration failed to track drug-induced changes in some cases, the HR and RR data of anesthetized rats measured from the radar sensor system showed comparable accuracy to other conventional methods.Keywords
Funding Information
- Kumamoto Regional Future Investment Promotion Project (146, 208)
This publication has 19 references indexed in Scilit:
- Remote sensing of vital signs by medical radar time-series signal using cardiac peak extraction and adaptive peak detection algorithm: Performance validation on healthy adults and application to neonatal monitoring at an NICUComputer Methods and Programs in Biomedicine, 2022
- A medical radar system for non-contact vital sign monitoring and clinical performance evaluation in hospitalized older patientsBiomedical Signal Processing and Control, 2022
- Improved Classification of Blood-Brain-Barrier Drugs Using Deep LearningScientific Reports, 2019
- No-touch measurements of vital signs in small conscious animalsScience Advances, 2019
- Twenty‐four‐hour continuous and remote monitoring of respiratory rate using a medical radar system for the early detection of pneumonia in symptomatic elderly bedridden hospitalized patientsClinical Case Reports, 2018
- A systematic review of novel technology for monitoring infant and newborn heart rateActa Paediatrica, 2017
- Noninvasive Measurement and Analysis of Laboratory Rat’s Cardiorespiratory MovementIEEE Transactions on Microwave Theory and Techniques, 2016
- Development of a noncontact and long‐term respiration monitoring system using microwave radar for hibernating black bearZoo Biology, 2009
- Marginal Hepatectomy in the RatAnnals of Surgery, 2006
- Prospective respiratory‐gated micro‐CT of free breathing rodentsMedical Physics, 2005