Protective effect of overlying geosynthetic on geomembrane liner observed from landfill field tests and inclined board laboratory experiments
Authors:
- 1 June 2006
- journal article
- research article
- Published by SAGE Publications in Waste Management & Research: The Journal for a Sustainable Circular Economy
- Vol. 24 (3) , 250-259
Abstract
Geosynthetic liner systems are generally installed in landfill sites to prevent toxic leachate from escaping into the adjoining environment by utilizing their impervious characteristics. Therefore, it is important to protect the geomembrane from being damaged or destroyed during all phases of landfilling, namely landfill construction, waste tipping and landfill closure. This paper presents firstly the observed performance of a geomembrane liner from a landfill site where the geomembrane liner was installed on the slopes of a Korean landfill; and secondly the results of an inclined board laboratory test. Two types of experiments were conducted to identify the protecting effect of the overlaying geosynthetic on the geomembrane liners. At a testing landfill site, the slope consisted of three different sub-inclines and two 2-m-wide intermediate levels. The sub-inclines were each 8 m in vertical height and their angle of inclination was 1: 1.5 (vertical: horizontal). The reported observations were made for a time period of approximately 1 year, until the landfill was filled with wastes to the top of the uppermost slope. In addition, inclined board laboratory tests were carried out. During the inclined board test, a base table is inclined slowly and steadily until the block located on the base table starts to slide, when the tension and displacements of two geosynthetics, namely the geomembrane liner and protecting geotextile, are measured. In conclusion, test results showed that the down-drag force generated by waste accumulation and sliding of upper material was to a large extent dissipated through the elongation of the protecting geosynthetic overlying the geomembrane and thus was not transferred to the geomembrane. Unless the protecting geosynthetic undergoes structural failure, this stress relaxation phenomenon continues to occur so that the magnitude of tensile force to be applied on the geomembrane remains marginal.Keywords
This publication has 4 references indexed in Scilit:
- Slope stability of lining systems—experimental modeling of friction at geosynthetic interfacesGeotextiles and Geomembranes, 2002
- Shear Behaviour of Geosynthetics in the Inclined Plane Test – Influence of Soil Particle Size and Geosynthetic StructureGeosynthetics International, 2001
- Geomembrane–sand interface frictional properties as determined by inclined board and shear box testsGeotextiles and Geomembranes, 1998