Abstract
The paper presents the effects of branches on powerline networks performance using recent developed model. The channels segments which have been compared are access, indoor and medium voltage channels. The comparison was done by varying different load at one of the terminals. The relationship between signal level and number of branches has been established. Quadrature amplitude modulation (QAM) is applied to the access channel model and attainable bit error rate (BER) against SNR analyzed and compared with possible transmitted power. It is observed that BER degrade as number of branches increases and SNR of about 4 dB is needed to attain the original performance without a branchKeywords
This publication has 6 references indexed in Scilit:
- Analysis of Multiconductor Transmission Lines2007
- A Novel Approach to the Modeling of the Indoor Power Line Channel—Part II: Transfer Function and Its PropertiesIEEE Transactions on Power Delivery, 2005
- Trends in telecommunication services provision: powerline network can provide alternative for access in developing countries2005
- Multipath Characterization of Indoor Power-Line NetworksIEEE Transactions on Power Delivery, 2005
- Modeling of Transfer Characteristics for the Broadband Power Line Communication ChannelIEEE Transactions on Power Delivery, 2004
- A multipath model for the powerline channelIEEE Transactions on Communications, 2002