Diamagnetic loop measurement in Korea Superconducting Tokamak Advanced Research machine
Authors:
- 1 June 2011
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 82 (6) , 063504
Abstract
Diamagnetic loop (DL), which consists of two poloidal loops inside the vacuum vessel, is used to measure the diamagnetic flux during a plasma discharge in the Korea Superconducting Tokamak Advanced Research (KSTAR) machine. The vacuum fluxes in the DL signal can be compensated up to 0.1 mWb by using the coefficients, which are obtained from experimental investigations, in the vacuum flux measurements during vacuum shots under same operational conditions of magnetic coils for plasma experiment in the KSTAR machine. The maximum error in the diamagnetic flux measurement due to the errors of the coefficients was estimated as ∼0.22 mWb. From the diamagnetic flux measurements for the ohmically heated circular plasmas in the KSTAR machine, the stored energy agrees well with the estimated kinetic energy within the discrepancy of 25%. When the electron cyclotron heating, the neutral beam injection, and the ion cyclotron resonance heating are added to the ohmically heated limiter plasmas, the additional heating effects can be clearly observed from the increase of the stored energy evaluated in the DL measurement.Keywords
This publication has 12 references indexed in Scilit:
- The first experimental results from x-ray imaging crystal spectrometer for KSTARReview of Scientific Instruments, 2010
- Plasma control system for “Day-One” operation of KSTAR tokamakFusion Engineering and Design, 2009
- A 280GHz single-channel millimeter-wave interferometer system for KSTARReview of Scientific Instruments, 2008
- Diamagnetic loop for the first plasma in the KSTAR machineReview of Scientific Instruments, 2008
- In-vessel visible inspection system on KSTARReview of Scientific Instruments, 2008
- Status of the KSTAR superconducting magnet system developmentNuclear Fusion, 2005
- Diamagnetic measurement on HT-7 superconducting tokamakFusion Engineering and Design, 2004
- Differential method for the real time measurement of the diamagnetic β and internal inductance in Tore SupraReview of Scientific Instruments, 2002
- Diamagnetic double-loop method for a highly sensitive measurement of energy stored in a Stellarator plasmaReview of Scientific Instruments, 2001