Haemodynamic Simulation and the Effect of Early Left Ventricular Unloading in Pre-Shock Acute Coronary Syndrome
Authors:
Open Access
- 12 March 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 6 (3) , 457-463
Abstract
Aims: Understanding the pathophysiological background on haemodynamic changes in acute myocardial infarction and during its interventional treatment is important to adequately use mechanical circulatory support. Methods and results: We describe haemodynamic simulations based on a real case scenario of infarct-related ischaemia with beginning haemodynamic compromise illustrating the advantage of active haemodynamic support. The patient case used for computer simulation is that of an acute coronary syndrome, slightly hypotonic. The right coronary artery is chronically occluded, and both left main and a saphenous vein graft to the left anterior descending coronary artery (LAD) show subtotal stenosis. In this scenario used for computer modelling of haemodynamics, we illustrate how unprotected percutaneous coronary intervention would limit coronary blood flow and constantly reduce myocardial contractility until cardiac arrest occurs. The simulation demonstrates how an intra-aortic balloon pump would delay but not prevent that compromise and how an Impella microaxial pump will actively support cardiac output and stabilize haemodynamics even when prolonged balloon inflations are performed, which will temporarily stop coronary perfusion. Conclusions: The simulation illustrates how temporary circulatory support with an Impella microaxial pump can stabilize haemodynamics and allow for a safe procedure in an unstable patient. Using computer simulation of haemodynamics to understand changes in haemodynamics when performing interventions in unstable patients might help to properly select a suitable support device if needed.Keywords
This publication has 19 references indexed in Scilit:
- Where next in cardiogenic shock owing to myocardial infarction?Nature Reviews Cardiology, 2015
- Recommendations on pre-hospital and early hospital management of acute heart failure: a consensus paper from the Heart Failure Association of the European Society of Cardiology, the European Society of Emergency Medicine and the Society of Academic Emergency Medicine – short versionEuropean Heart Journal, 2015
- 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular CareJACC, 2015
- 2014 ESC/EACTS Guidelines on myocardial revascularizationEuropean Heart Journal, 2014
- 2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial InfarctionCirculation, 2013
- 2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction: Executive SummaryCirculation, 2013
- Intraaortic Balloon Support for Myocardial Infarction with Cardiogenic ShockNew England Journal of Medicine, 2012
- A Prospective, Randomized Clinical Trial of Hemodynamic Support With Impella 2.5 Versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary InterventionCirculation, 2012
- Improvement of myocardial perfusion with a percutaneously inserted left ventricular assist deviceJournal of Nuclear Cardiology, 2010
- Left ventricular support by Catheter-Mountedaxial flow pump reduces infarct sizeJACC, 2003