Mass fragmentographic assay for 25‐hydroxyvitamin D in plasma without derivatization: Enhanced sensitivity for metabolites of vitamins D2 and D3 after pre‐column dehydration
Authors:
- 1 February 1995
- journal article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 30 (2) , 348-356
Abstract
A mass fragmentographic method for the measurement in plasma of underivatized, dehydrated 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 was developed. Quantitative dehydration of vitamin D metabolites was achieved prior to gas chromatography using a new high‐temperature injection system and a small precolumn packed with aluminium powder in the injection port, followed by mass fragmentography on an inexpensive bench‐top mass spectrometer. Plasma (2 ml) was incubated with hexadeuteriated 25‐hydroxyvitamin D3 prior to acetonitrile extraction and purification using cartridges pre‐packed with microparticulate silica using reversed‐ and normal‐phase solvent systems. After purification, capillary gas chromatography mass spectrometry was carried out following dehydration of the secosteroids on the aluminium power pre‐column at 400°C. High‐intensity dehydrated molecular ions were produced which were used for selected ion monitoring. The assay sensitivity for 25‐hydroxyvitamin D was approximately 1 ng ml−1. The intra‐assay variation was less than 7% and the recovery of added standard was quantitative. It is suggested that this method may be used to provide target values for much needed quality control schemes to monitor assays routinely used in the estimation of 25‐hydroxyvitamin D. The behaviour of a number of other hydroxylated vitamin D metabolites, when injected without derivatization on to a gas chromatographic column, was also investigated.Keywords
This publication has 10 references indexed in Scilit:
- Gas chromatography—mass spectrometry in the investigation of on-column dehydration of steroid hormones during gas—liquid chromatographyJournal of Pharmaceutical and Biomedical Analysis, 1991
- ASSAYS FOR VITAMIN D AND ITS METABOLITES: DO WE NEED TO IMPROVE ACCURACY AND PRECISION?1991
- Recent developments in the measurement of vitamin D and its metabolites in human body fluidsJournal of Steroid Biochemistry, 1987
- Gas chromatography—mass spectrometry and the measurement of vitamin D metabolites in human serum or plasmaSteroids, 1987
- Specific mass fragmentographic assay for 25,26-dihydroxyvitamin D in human plasma using a deuterated internal standardJournal of Chromatography B: Biomedical Sciences and Applications, 1985
- Interlaboratory comparison of 25-hydroxyvitamin D determination.Clinical Chemistry, 1984
- Specific estimation of 24,25-dihydroxyvitamin D in plasma by gas chromatography-mass spectrometry.Clinical Chemistry, 1984
- An international comparison of vitamin D metabolite measurements.Clinical Chemistry, 1984
- Determination of 25-Hydroxyvitamin D3in Serum by High Performance Liquid Chromatography and Isotope Dilution—Mass SpectrometryScandinavian Journal of Clinical and Laboratory Investigation, 1984
- The estimation of vitamin D and some metabolites in human plasma by mass fragmentographyClinica Chimica Acta, 1980