Chemical sensors based on SAW resonators working at up to 1 GHz
Authors:
- F. DickertFDF. Dickert
- P. ForthPFP. Forth
- U. KnauerUKU. Knauer
- 24 December 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (10510117) , 439-442
Abstract
We have investigated SAW chemical sensors working at 434 MHz and at 1 GHz, the latter frequency being the highest value reported in this context to date. In particular, the theoretical claim that the gas sensitivity is proportional to the frequency has been checked experimentally. The results of a noise characterization clearly show that the detection limit decreases with frequency even when noise is taken into account. By using molecular cavity compounds such as calixarenes, cyclodextrines and cyclophanes or "molecularly imprinted" polymers as chemically sensitive coatings, sub-ppm traces of halogenated and aromatic hydrocarbons such as toluene or xylene have been detected under ambient conditions.Keywords
This publication has 6 references indexed in Scilit:
- Supramolecular receptors for SAW and QMB devices: solvent recognition evaluated by FT-IR spectroscopy and BET adsorption analysisSensors and Actuators B: Chemical, 1995
- Acoustic Wave Devices1995
- Supramolecular detection of solvent vapours with QMB and SAW devicesSensors and Actuators B: Chemical, 1993
- Precision surface-acoustic-wave (SAW) oscillatorsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1988
- Mechanism of operation and design considerations for surface acoustic wave device vapour sensorsSensors and Actuators, 1984
- Direct Phase Noise Measurements of SAW Resonators1984