A natural inhibitor of pitting corrosion of copper in tap‐waters
Author:
- 1 December 1954
- journal article
- research article
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 4 (12) , 633-647
Abstract
Many supply waters that might be expected to cause pitting corrosion in copper cold‐water pipes containing carbon films do not do so because they contain a natural inhibitor. The inhibitor has not been identified, but it can be shown to be present in these waters and its concentration can be compared roughly with a standard. The inhibitor, which is considered to be of organic origin, is associated with bluish‐white fluorescence in ultra‐violet light, and with depression of the maximum normally present in the polarograms of waters containing dissolved oxygen. It causes cuprous oxide to be formed at corroding copper anodes as a fine‐grained, dull‐brown adherent film instead of as coarse, red non‐adherent crystals. The latter property accounts for its inhibiting effect.Keywords
This publication has 3 references indexed in Scilit:
- Treatment of Paper for Chromatography of some Colloidal ElectrolytesNature, 1950
- Interferometrische Beobachtungen über Strömungsanomalien an KathodenBerichte der Bunsengesellschaft für physikalische Chemie, 1937
- Polarographic studies with the dropping mercury electrode. Part III. The cause of maxima on curent-voltage curvesCollection of Czechoslovak Chemical Communications, 1936