Reducing Noises and Artifacts Simultaneously of Low‐Dosed X‐Ray Computed Tomography Using Bilateral Filter Weighted by Gaussian Filtered Sinogram
Authors:
Open Access
- 1 January 2012
- journal article
- research article
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2012 (1)
Abstract
Existing sinogram restoration methods cannot handle noises and nonstationary artifacts simultaneously. Although bilateral filter provides an efficient way to preserve image details while denoising, its performance in sinogram restoration for low‐dosed X‐ray computed tomography (LDCT) is unsatisfied. The main reason for this situation is that the range filter of the bilateral filter measures similarity by sinogram values, which are polluted seriously by noises and nonstationary artifacts of LDCT. In this paper, we propose a simple method to obtain satisfied restoration results for sinogram of LDCT. That is, the range filter weighs the similarity by Gaussian smoothed sinogram. Since smoothed sinogram can reduce the influence of both noises and nonstationary artifacts for similarity measurement greatly, our new method can provide more satisfied denoising results for sinogram restoration of LDCT. Experimental results show that our method has good visual quality and can preserve anatomy details in sinogram restoration even in both noises and non‐stationary artifacts.Keywords
Funding Information
- National Natural Science Foundation of China (60873102, 2010CB732501), J2010N03, 2009AA12Z140)
- National Basic Research Program of China (60873102, 2010CB732501), J2010N03, 2009AA12Z140)
- Open Foundation of Visual Computing and Virtual Reality Key Laboratory of Sichuan Province (60873102, 2010CB732501), J2010N03, 2009AA12Z140)
- National High Technology Research and Development Program of China (60873102, 2010CB732501), J2010N03, 2009AA12Z140)
This publication has 40 references indexed in Scilit:
- Strategies for Dose-Optimized Imaging in Pediatric Cardiac Dual Source CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2009
- The relevance of image quality indices for dose optimization in abdominal multi-detector row CT in children: experimental assessment with pediatric phantomsPhysics in Medicine & Biology, 2009
- Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CTKorean Journal of Radiology, 2009
- Survival and radiation risk in patients obtaining more than six CT examinations during one yearActa Oncologica, 2009
- The influence of bowtie filtration on cone‐beam CT image qualityMedical Physics, 2008
- Penalized maximum-likelihood sinogram restoration for dual focal spot computed tomographyPhysics in Medicine & Biology, 2007
- Penalized‐likelihood sinogram smoothing for low‐dose CTMedical Physics, 2005
- Image denoising using scale mixtures of gaussians in the wavelet domainIEEE Transactions on Image Processing, 2003
- Fundamental relationship between bilateral filtering, adaptive smoothing, and the nonlinear diffusion equationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2002
- Statistical image reconstruction for polyenergetic X-ray computed tomographyIEEE Transactions on Medical Imaging, 2002