High-Volume Aerosol Filtration and Mitigation of Inertial Particle Rebound
Open Access
- 25 February 2014
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 48 (5) , 530-540
Abstract
The performance of electrostatically charged blown microfiber filter media was characterized for high-volume sampling applications. Pressure drop and aerosol collection efficiency were measured at air pressures of 55.2 and 88.7 kilopascals (kPa) and filter face velocities ranging from 2.5 to 11.25 meters per second (m/s). Particle penetration was significant for particles above 0.5 micrometers (μm) in aerodynamic diameter where the onset of particle rebound was observed as low as 200 nanometers (nm). Particle retention was enhanced by treating filters in an aqueous solution of glycerol. Adding this retention agent eliminated electrostatic capture mechanisms but mitigated inertial rebound. Untreated filters had higher nanoparticle collection efficiencies at lower filter face velocities where electrostatic capture was still significant. At higher filter face velocities, nanoparticle collection efficiencies were higher for treated filters where inertial capture was dominant and particle rebound was mitigated. Significant improvements to microparticle collection efficiency were observed for treated filters at all air flow conditions. At high air pressure, filter efficiency was greater than 95% for particles less than 5 μm. At low air pressure, performance enhancements were not as significant since air velocities were significantly higher through the fiber mat. Measured single fiber efficiencies were normalized by the theoretical single fiber efficiency to calculate adhesion probability. The small fiber diameter (1.77 μm) of this particular filter gave large Stokes numbers and interception parameters forcing the single fiber efficiency to its maximum theoretical value. The adhesion probability was plotted as a function of the ratio of Stokes and interception parameter similar to the works of others. Single fiber efficiencies for inertial nanoparticle collection were compared to existing theories and correlations. Copyright 2014 American Association for Aerosol ResearchKeywords
This publication has 22 references indexed in Scilit:
- Aerosol Collection Efficiency of a Graded Metal-Fiber Filter at High Airflow Velocity (10 m s–1)Aerosol Science and Technology, 2011
- Structure and density of deposits formed on filter fibers by inertial particle deposition and bounceJournal of Aerosol Science, 2010
- Particle Bounce During Filtration of Particles on Wet and Dry FiltersAerosol Science and Technology, 2003
- Effects of particle polydispersity and shape factor during dust cake loading on air filtersPowder Technology, 1998
- Experimental Study of Electrostatic Capture Mechanisms in Commercial Electret FiltersAerosol Science and Technology, 1998
- Particle Bounce or Capture—Search for an Adequate Theory: I. Conservation-of-Energy Model for a Simple Collision ProcessAerosol Science and Technology, 1995
- Experimental Investigation of Particle Collection on Single Fibres of Different ConfigurationsParticle & Particle Systems Characterization, 1994
- The permeability of fibrous porous mediaThe Canadian Journal of Chemical Engineering, 1986
- Aerosol filtration by fibrous filters at intermediate Reynolds numbers (≤ 100)Atmospheric Environment (1967), 1974
- The pressure drop of a fibrous filter at reduced ambient pressuresJournal of Aerosol Science, 1972