A structural investigation of corneal graft failure in suspected recurrent keratoconus
Authors:
- 3 July 2009
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 24 (4) , 728-734
Abstract
Penetrating keratoplasty was performed on the right eye of a 51-year-old patient diagnosed with advanced bilateral keratoconus. Thirteen years later, an 8.5 mm regraft was required as a result of gross vascularisation, a poor epithelium, and suspected recurrent keratoconus. To learn more about the structural basis for graft failure, we examined the removed tissue for the presence of abnormalities in the stroma and limiting membranes. X-ray scattering and electron microscopy were used to study the failed-graft tissue to provide information on the integrity of the limiting membranes and the diameter, dominant orientation, and distribution of collagen within the corneal stroma. The findings were compared with similar structural data from normal and keratoconus corneas. In contrast to the keratoconus cornea, a normal orientation and distribution of collagen was seen throughout most of the failed-graft tissue, although abnormalities were observed in the infero-nasal quadrant at the original graft/host junction. The average diameter of collagen fibrils in the failed-graft button did not differ from that of normal corneas. The structural abnormalities identified in this case of graft failure were not consistent with those typically seen in keratoconus. The clear demarcation of the graft/host boundary 13 years after surgery suggests that a normal stromal collagen arrangement may never be fully achieved in corneal graft wounds.Keywords
This publication has 18 references indexed in Scilit:
- Recurrence of Keratoconus in Two Corneal Grafts After Penetrating KeratoplastyCornea, 2007
- Extended Long-term Outcomes of Penetrating Keratoplasty for KeratoconusOphthalmology, 2006
- Mapping Collagen Organization in the Human Cornea: Left and Right Eyes Are Structurally DistinctInvestigative Ophthalmology & Visual Science, 2006
- Changes in Collagen Orientation and Distribution in Keratoconus CorneasInvestigative Ophthalmology & Visual Science, 2005
- Penetrating keratoplasty: indications over a 10 year periodBritish Journal of Ophthalmology, 2004
- X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and LimbusStructure, 2004
- X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and LimbusStructure, 2004
- Indications for Penetrating Keratoplasty and Associated Procedures, 1996–2000Cornea, 2002
- Penetrating keratoplasty for keratoconus: visual outcome and success11The authors have no proprietary interest related to this article.Ophthalmology, 2000
- Recurrence of keratoconus in donor cornea 22 years after successful keratoplasty.British Journal of Ophthalmology, 1983