Environmentally friendly surface modification of PDMS using PEG polymer brush
Authors:
- 17 September 2009
- journal article
- microfluidics and-miniaturization
- Published by Wiley in Electrophoresis
- Vol. 30 (18) , 3174-3180
Abstract
A PEG‐NH2‐based environmentally friendly surface modification strategy was developed for PDMS microchips to prevent protein adsorption and to enhance separation performance. PEG‐NH2 was synthesized using a modified synthesis procedure. A two‐step grafting method was used for PDMS modification. FTIR absorption by attenuated total reflection and contact angle measurements verified the successful grafting of PEG‐NH2 onto the PDMS surface. Subsequent EOF Measurements and protein adsorption studies of PEG‐modified PDMS microchips revealed noticeable EOF suppression and resistance to nonspecific protein adsorption for more than 30 days. Separation of four FITC‐labeled amino acids was further demonstrated with high repeatability and reproducibility. Comparison of electrophoresis of 3‐(2‐furoyl)quinoline‐2‐carboxaldehyde‐labeled BSA using PDMS microchips before and after surface modification resulted in significantly improved electrophoretic performance of the PEG‐modified PDMS microchips, suggesting that our PEG grafting method successfully modified PDMS surface property and prevented adsorption of proteins. We expect that this environmentally friendly surface modification method will be useful for future protein separations with long‐term surface stability.Keywords
This publication has 39 references indexed in Scilit:
- New approaches to target microsomal triglyceride transfer proteinCurrent Opinion in Lipidology, 2008
- Functional Nanoparticle-Based Proteomic Strategies for Characterization of Pathogenic BacteriaAnalytical Chemistry, 2008
- The multiple lives of NMD factors: balancing roles in gene and genome regulationNature Reviews Genetics, 2008
- Structural Biology of the Tumor Suppressor p53Annual Review of Biochemistry, 2008
- High resolution proteome/peptidome analysis of body fluids by capillary electrophoresis coupled with MSProteomics, 2006
- Metallodrug research and analysis using capillary electrophoresisTrAC Trends in Analytical Chemistry, 2006
- Two-Dimensional Microcolumn Separation Platform for Proteomics Consisting of On-Line Coupled Capillary Isoelectric Focusing and Capillary Electrochromatography. 1. Evaluation of the Capillary-Based Two-Dimensional Platform with Proteins, Peptides, and Human SerumJournal of Proteome Research, 2006
- LC–tandem MS in proteome characterizationTrAC Trends in Analytical Chemistry, 2005
- Preparation of 20-μm-i.d. Silica-Based Monolithic Columns and Their Performance for Proteomics AnalysesAnalytical Chemistry, 2005
- Prefractionation techniques in proteome analysis: The mining tools of the third millenniumElectrophoresis, 2005