A Grid-Based Nucleus Counting Method for Estimates of the Density of Superficial Conjunctival Cells from Impression Cytology Samples Taken from Normal Healthy Human Eyes
- 30 May 2017
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 42 (9) , 1228-1234
Abstract
Purpose: To develop and validate an easily procured objective estimate of the cell density of the superficial epithelial cells of the normal bulbar conjunctiva using conjunctival impression cytology (CIC). Methods: From 20 healthy non-contact lens-wearing young adults, CIC was undertaken off the nasal aspect of the exposed bulbar conjunctiva, the filters stained with Giemsa, and images taken at 200× that only included an all-but-contiguous monolayer of epithelial cells. These images were projected at 1000× magnification and an overlay drawn of the location of the stained nuclei, from which two types of analysis were undertaken using either 100 micron circular or square regions of interest (ROI). From the former, the distances between all nuclei were measured and the number of nuclei/circle calculated to establish uniformity of cell nuclei distribution as a necessary prerequisite to using a grid-based counting method. From the latter, the number of nuclei in each square grid was manually counted and the grid-by-grid variability assessed. Results: The average inter-nucleus distance was 16.1+/3.5 microns, with predictable positioning to successive nuclei in the circular ROI to give an estimated numerical density of 1944 ± 237/sq mm. Counting of nuclei in grid squares yielded numbers between 12 and 42 to yield an estimated cell density of 2390 +/ ̶330 /sq mm, with repeat counts off grid square ROIs being predictably within +/–15%. Conclusions: These studies indicate that it should be fairly easy to use carefully selected CIC samples to make estimates of the density of the superficial conjunctival cells. Such a method should be useful and offer advantage over the subjective assignment of morphological grades to CIC samples which have been shown to be highly variable.Keywords
Funding Information
- None (none)
This publication has 23 references indexed in Scilit:
- Assessment of Consistency in Assignment of Severe (Grade 3) Squamous Metaplasia to Human Bulbar Conjunctiva Impression Cytology Cell SamplesThe Ocular Surface, 2015
- Objective Assessment of Squamous Metaplasia of Conjunctival Epithelial Cells as Associated With Soft Contact Lens Wear Versus Non–Lens WearersCornea, 2014
- Comparative Anatomy and Physiology of the Cornea and Conjunctiva2012
- Objective Assessment of Contact Lens Wear-Associated Conjunctival Squamous Metaplasia by Linear Measures of Cell Size, Shape and Nucleus-to-Cytoplasm RatiosCurrent Eye Research, 2011
- Objective assessment of conjunctival squamous metaplasia by measures of cell and nucleus dimensionsDiagnostic Cytopathology, 2011
- Assessment of agreement for assignment of a normal grade to human conjunctival impression cytology samplesCytopathology, 2010
- Impression Cytology: Recent Advances and Applications in Dry Eye DiseaseThe Ocular Surface, 2009
- Impression cytology of the ocular surface: a reviewExperimental Eye Research, 2004
- Further analysis of the size and shape of cells obtained by impression cytology from the exposed portion of the human bulbar conjunctivaOphthalmic and Physiological Optics, 2000
- Staging of Conjunctival Squamous Metaplasia by Impression CytologyOphthalmology, 1985