Abstract
AP102 is a di‐iodinated octapeptide somatostatin agonist (SSA) designed to treat acromegaly and neuroendocrine tumors. A sensitive and selective method was validated for the quantification of AP102 in plasma following the European Medicines Agency (EMA) and Food and Drug Administration (FDA) guidelines. Sample preparation was performed using solid‐phase extraction microplates. Chromatographic separation was achieved on an ultra‐high pressure liquid chromatography (UHPLC) C18 column in 6.0 minutes. The compounds were quantified using multiple reaction monitoring on a tandem quadrupole mass spectrometer with 13C,15N‐labeled AP102 as internal standard. Calibration ranged from 50 to 10000 pg/mL. The lower limit of quantification (LLOQ) was measured at 20 pg/mL, and robust analytical performances were obtained with trueness at 99.2%–100.0%, intra‐assay imprecision at 2.5%–4.4%, and inter‐assay imprecision at 8.9%–9.7%. The accuracy profiles (total error) built on the 3 concentrations levels showed accuracy within the 70%–130% range. AP102 is remarkably stable since no proteolytic fragments were detected on plasma samples analyzed by Orbitrap‐MS. Pharmacokinetic studies were conducted in rats, after single dose (1, 3, and 10 μg/kg, sc) and continuous subcutaneous administration (osmotic minipumps for 28 days, 3.0 or 10.0 μg/kg/h). AP102 showed a rapid absorption by the subcutaneous route (Tmax: 15–30 minutes) and a fast elimination (t1/2: 33–86 minutes). The PK profile of AP102 exhibited a mean clearance of 1.67 L/h and a mean distribution volume at steady state of 7.16 L/kg, about 10‐fold higher than those observed with other SSA or non‐ and mono‐iodinated AP102. LogD7.4 determination confirmed the lipophilic properties of AP102 that might influence its distribution in tissues.Keywords
Funding Information
- Swiss Commission for Technology and Innovation (15808.1PFLS)
This publication has 28 references indexed in Scilit:
- Effects of somatostatin analogs on glucose homeostasis in ratsJournal of Endocrinology, 2011
- Determination of octreotide and assessment of matrix effects in human plasma using ultra high performance liquid chromatography–tandem mass spectrometryJournal of Chromatography B, 2011
- The importance of using the optimal plasticware and glassware in studies involving peptidesAnalytical Biochemistry, 2011
- Biocompatibility of an Injectable In Situ Forming Depot for Peptide DeliveryJournal of Pharmaceutical Sciences, 2010
- Determination of long‐acting release octreotide, an octapeptide analogue of somatostation, in human plasma by liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2007
- Discovery of Iodinated Somatostatin Analogues Selective for hsst2 and hsst5 with Excellent Inhibition of Growth Hormone and Prolactin Release from Rat Pituitary CellsJournal of Medicinal Chemistry, 2005
- In vivo release kinetics of octreotide acetate from experimental polymeric microsphere formulations using oil/water and oil/oil processesAAPS PharmSciTech, 2004
- Pharmacokinetics of a new Autogel formulation of the somatostatin analogue lanreotide after a single subcutaneous dose in healthy volunteersJournal of Pharmacy and Pharmacology, 2004
- Clinical Pharmacokinetics of OctreotideClinical Pharmacokinetics, 1993
- Hypothalamic Polypeptide That Inhibits the Secretion of Immunoreactive Pituitary Growth HormoneScience, 1973