Flexible, Graphene‐Coated Biocomposite for Highly Sensitive, Real‐Time Molecular Detection
- 15 November 2016
- journal article
- research article
- Published by Wiley in Advanced Functional Materials
- Vol. 26 (47) , 8623-8630
Abstract
Wearable biosensors hold significant potential for healthcare and environmental applications, and the development of flexible and biocompatible sensing platforms for high accuracy detection of physiological biomarkers remains an elusive goal. Herein, an ultrasensitive, flexible sensor is described that is based on a 3D hierarchical biocomposite comprised of hollow, natural pollen microcapsules that are coated with a conductive graphene layer. Modular assembly of the graphene‐coated microcapsules onto an ultrathin polyethylene terephthalate layer enables a highly flexible sensor configuration with tunable selectivity afforded by subsequent covalent immobilization of antibodies against target antigens. In a proof‐of‐concept example, the biosensor demonstrates ultrahigh sensitivity detection of prostate specific antigen (PSA) down to 1.7 × 10−15m with real‐time feedback and superior performance over conventional 2D graphene‐coated sensors. Importantly, the device performance is consistently high across various bending conditions. Taken together, the results demonstrated in this work highlight the merits of employing lightweight biocomposites as modular building blocks for the design of flexible biosensors with highly responsive and sensitive molecular detection capabilities.Keywords
Funding Information
- China Postdoctoral Science Foundation (2015M571361)
This publication has 43 references indexed in Scilit:
- Label‐Free Polypeptide‐Based Enzyme Detection Using a Graphene‐Nanoparticle Hybrid SensorAdvanced Materials, 2012
- Hybrids of a Genetically Engineered Antibody and a Carbon Nanotube Transistor for Detection of Prostate Cancer BiomarkersACS Nano, 2012
- The Enzymatic Oxidation of Graphene OxideACS Nano, 2011
- Frequency Domain Detection of Biomolecules Using Silicon Nanowire BiosensorsNano Letters, 2010
- Subthreshold Regime has the Optimal Sensitivity for Nanowire FET BiosensorsNano Letters, 2009
- Enhancement of sensitivity and specificity by surface modification of carbon nanotubes in diagnosis of prostate cancer based on carbon nanotube field effect transistorsBiosensors and Bioelectronics, 2009
- Measurement of the Elastic Properties and Intrinsic Strength of Monolayer GrapheneScience, 2008
- Selective Targeting and Potent Control of Tumor Growth Using an EphA2/CD3-Bispecific Single-Chain Antibody ConstructCancer Research, 2007
- Prostate-specific antigen in clinical practiceCancer Letters, 2007
- Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical SpeciesScience, 2001