Advanced Multiplex Loop Mediated Isothermal Amplification (mLAMP) Combined with Lateral Flow Detection (LFD) for Rapid Detection of Two Prevalent Malaria Species in India and Melting Curve Analysis
Open Access
- 24 December 2021
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 12 (1) , 32
Abstract
Isothermal techniques with lateral flow detection have emerged as a point of care (POC) technique for malaria, a major parasitic disease in tropical countries such as India. Plasmodium falciparum and Plasmodium vivax are the two most prevalent malaria species found in the country. An advanced multiplex loop-mediated isothermal amplification (mLAMP) combined with a lateral flow dipstick (LFD) technique was developed for the swift and accurate detection of P. falciparum and P. vivax, overcoming the challenges of the existing RDTs (rapid diagnostic tests). A single set of LAMP primers with a biotinylated backward inner primer (BIP primer) was used for DNA amplification of both malaria species in a single tube. The amplified DNA was hybridized with fluorescein isothiocyanate (FITC) and digoxigenin-labelled DNA probes, having a complemented sequence for the P. falciparum and P. vivax genomes, respectively. A colour band appeared on two separate LFDs for P. falciparum and P. vivax upon running the hybridized solution over them. In total, 39 clinical samples were collected from ICMR-NIMR, New Delhi. Melting curve analysis, with cross primers for both species, was used to ascertain specificity, and the sensitivity was equated with a polymerase chain reaction (PCR). The results were visualized on the LFD for both species within 60 min. We found 100% sensitivity and specificity, when compared with a traditional PCR. Melting curve analysis of mLAMP revealed the lowest detection limit of 0.15 pg/μL from sample genomic DNA. The mLAMP-LFD assays could be a potential point of care (POC) tool for early diagnosis in non-laboratory conditions, with the convenience of a reduced assay time and the simple interpretation of results.Keywords
Funding Information
- Indian Council of Medical Research (3/1/3/PDF (16)/2017-HRD)
This publication has 31 references indexed in Scilit:
- Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCRMalaria Journal, 2015
- Application of loop-mediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivaxParasitology International, 2014
- Micromagnetic resonance relaxometry for rapid label-free malaria diagnosisNature Medicine, 2014
- Loop-mediated isothermal amplification test for the molecular diagnosis of malariaExpert Review of Molecular Diagnostics, 2013
- A novel, single-amplification PCR targeting mitochondrial genome highly sensitive and specific in diagnosing malaria among returned travellers in Bergen, NorwayMalaria Journal, 2013
- Ambient temperature detection of PCR amplicons with a novel sequence-specific nucleic acid lateral flow biosensorBiosensors and Bioelectronics, 2012
- Dry-reagent gold nanoparticle-based lateral flow biosensor for the simultaneous detection of Vibrio cholerae serogroups O1 and O139Journal of Microbiological Methods, 2011
- Analyzing real-time PCR data by the comparative CT methodNature Protocols, 2008
- Development of a loop-mediated isothermal amplification method for diagnosing Pneumocystis pneumoniaJournal of Medical Microbiology, 2008
- Real-Time PCR for Detection and Identification of Plasmodium sppJournal of Clinical Microbiology, 2005