Estimating real-time infiltration for use in residential ventilation control
Authors:
- 26 August 2019
- journal article
- research article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 29 (4) , 508-526
Abstract
Minimum outdoor air ventilation rates specified in standards such as ASHRAE Standard 62.2–2016 are generally based on envelope airtightness, building floor area, geographical location and number of occupants. ASHRAE Standard 62.2–2016 allows for a constant infiltration credit, which reduces the required mechanical ventilation. However, infiltration rates vary based on the weather and system operation. Thus, mechanical systems could potentially operate less if the real-time (RT) infiltration rate was known and used to adjust the mechanical ventilation rate. CONTAM models of two test houses on the campus of the National Institute of Standards and Technology were verified with measurements and used to simulate hourly infiltration rates in three cities. The infiltration rates were passed to a theoretical controller that changed the hourly mechanical ventilation rate to meet the ventilation requirement. Simulated energy use and relative annual occupant exposure for this RT control strategy were compared with ventilation at a constant rate. Implementation of the RT control strategy resulted in annual average energy savings of $66USD across both houses and three cities without increasing the annual occupant exposure compared with ventilating continuously at a constant rate. The authors discuss the advantages and limitations of the proposed RT ventilation control strategy.Keywords
Funding Information
- the National Center for Healthy Housing (CRADA CN-17-0080)
This publication has 18 references indexed in Scilit:
- Efficacy of occupancy-based smart ventilation control strategies in energy-efficient homes in the United StatesBuilding and Environment, 2019
- Smart ventilation energy and indoor air quality performance in residential buildings: A reviewEnergy and Buildings, 2018
- Coupling the multizone airflow and contaminant transport software CONTAM with EnergyPlus using co-simulationBuilding Simulation, 2016
- Field measurement of ventilation ratesIndoor Air, 2015
- Demand-controlled ventilation in new residential buildings: Consequences on indoor air quality and energy savingsIndoor and Built Environment, 2013
- Advanced Controls and Sustainable Systems for Residential Ventilation2012
- Meeting residential ventilation standards through dynamic control of ventilation systemsEnergy and Buildings, 2011
- Validation of multizone IAQ model predictions for tracer gas in a townhouseBuilding Services Engineering Research & Technology, 2004
- A Comprehensive Validation of Two Airflow Models - COMIS and CONTAMIndoor Air, 1996
- Development and Validation of a Multizone Model for Overall Indoor Air Environment PredictionHVAC&R Research, 1996