Thermal Ablation of Liver Tumors Guided by Augmented Reality: An Initial Clinical Experience
Authors:
- Marco SolbiatiMSMarco Solbiati
- Tiziana IeraceTITiziana Ierace
- Riccardo MugliaRMRiccardo Muglia
- Vittorio PediciniVPVittorio Pedicini
- Roberto IezziRoberto Iezzi
- Katia M. PasseraKPKatia M. Passera
- Alessandro C. RotilioARAlessandro C. Rotilio
- S. Nahum GoldbergSGS. Nahum Goldberg
- Luigi A. SolbiatiLuigi A. Solbiati
Open Access
Abstract
Background: Over the last two decades, augmented reality (AR) has been used as a visualization tool in many medical fields in order to increase precision, limit the radiation dose, and decrease the variability among operators. Here, we report the first in vivo study of a novel AR system for the guidance of percutaneous interventional oncology procedures. Methods: Eight patients with 15 liver tumors (0.7–3.0 cm, mean 1.56 + 0.55) underwent percutaneous thermal ablations using AR guidance (i.e., the Endosight system). Prior to the intervention, the patients were evaluated with US and CT. The targeted nodules were segmented and three-dimensionally (3D) reconstructed from CT images, and the probe trajectory to the target was defined. The procedures were guided solely by AR, with the position of the probe tip was subsequently confirmed by conventional imaging. The primary endpoints were the targeting accuracy, the system setup time, and targeting time (i.e., from the target visualization to the correct needle insertion). The technical success was also evaluated and validated by co-registration software. Upon completion, the operators were assessed for cybersickness or other symptoms related to the use of AR. Results: Rapid system setup and procedural targeting times were noted (mean 14.3 min; 12.0–17.2 min; 4.3 min, 3.2–5.7 min, mean, respectively). The high targeting accuracy (3.4 mm; 2.6–4.2 mm, mean) was accompanied by technical success in all 15 lesions (i.e., the complete ablation of the tumor and 13/15 lesions with a >90% 5-mm periablational margin). No intra/periprocedural complications or operator cybersickness were observed. Conclusions: AR guidance is highly accurate, and allows for the confident performance of percutaneous thermal ablations.Keywords
This publication has 46 references indexed in Scilit:
- Navigational Tools for Interventional Radiology and Interventional Oncology ApplicationsSeminars in Interventional Radiology, 2015
- CT-Guided Liver Biopsy With Electromagnetic Tracking: Results From a Single-Center Prospective Randomized Controlled TrialAmerican Journal of Roentgenology, 2014
- Robotic systems for percutaneous needle-guided interventionsMinimally Invasive Therapy & Allied Technologies, 2014
- Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria—A 10-Year UpdateRadiology, 2014
- Real-Time US-CT/MRI Image Fusion for Guidance of Thermal Ablation of Liver Tumors Undetectable with US: Results in 295 CasesCardioVascular and Interventional Radiology, 2014
- Augmented reality in laparoscopic surgical oncologySurgical Oncology, 2011
- Real-Time 3D Fluoroscopy Guidance During Needle Interventions: Technique, Accuracy, and FeasibilityAmerican Journal of Roentgenology, 2010
- Three-dimensional C-arm Cone-beam CT: Applications in the Interventional SuiteJournal of Vascular and Interventional Radiology, 2009
- Augmented reality guidance for needle biopsies: An initial randomized, controlled trial in phantoms††A preliminary version of this paper was presented at the Medical Image Computing and Computer-Assisted Intervention (MICCAI) 2001 conference in Utrecht. The Netherlands (Rosenthal et al., 2001)Medical Image Analysis, 2002
- 1996 RSNA Eugene P. Pendergrass New Horizons Lecture. Image-guided procedures and the operating room of the future.Radiology, 1997