Calibration of a rotating 2D LRF in unprepared environments by minimizing redundant measurement errors
Authors:
- 1 July 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 172-177
Abstract
This paper proposes a calibration method for a 3D laser scanning system built with a rotating 2D laser rangefinder (LRF) in unprepared environments. Although the combination of a 2D LRF with a rotating unit yields a low-cost and compact 3D scanner, construction misalignments must be calibrated to reduce measurement error. Existing calibration techniques are generally used either with a special target object or in prepared environments with flat surfaces, and this imposes a limitation on the applicable domain of the system. To solve this problem, we propose a novel calibration method using redundant measurements of 3D point clouds. The main idea of the proposed method is to focus on the fact that rotating LRF systems observe the same object twice during a single rotation at different times. Therefore, by minimizing the extent of misalignment of these redundant measurements, we can estimate the calibration parameters without using any special target object. We formulate this calibration by redundant measurements as a non-linear cost minimization problem. The results of the simulation and real-world experiments in challenging, real environments show that the proposed method works well in unprepared and even cluttered environments.Keywords
This publication has 12 references indexed in Scilit:
- A topological enabled three-dimensional model based on constructive solid geometry and boundary representationCluster Computing, 2016
- Full-DOF Calibration of a Rotating 2-D LIDAR With a Simple Plane MeasurementIEEE Transactions on Robotics, 2016
- The 3D laser range finder design for the navigation and mapping for the coal mine robot2016
- Calibration of Short Range 2D Laser Range Finder for 3D SLAM UsageJournal of Sensors, 2015
- 3D Convolutional Neural Networks for landing zone detection from LiDAR2015
- Construction and calibration of a low-cost 3D laser scanner with 360° field of view for mobile robots2015
- Boresight Calibration of Construction Misalignments for 3D Scanners Built with a 2D Laser Rangefinder Rotating on Its Optical CenterSensors, 2014
- 3D Object Recognition in Cluttered Scenes with Local Surface Features: A SurveyIEEE Transactions on Pattern Analysis and Machine Intelligence, 2014
- Self-calibration for a 3D laserThe International Journal of Robotics Research, 2011
- A Simplex Method for Function MinimizationThe Computer Journal, 1965