Magnetic susceptibility matching at the air–tissue interface in rat lung by using a superparamagnetic intravascular contrast agent: Influence on transverse relaxation time of hyperpolarized helium‐3
- 20 June 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (1) , 28-33
Abstract
Transverse relaxation of hyperpolarized helium‐3 magnetization in respiratory airways highly depends on local magnetic field gradients induced by the magnetic susceptibility difference between gas and pulmonary tissue. Fast transverse relaxation is known to be an important feature that yields information about lung microstructure and function, but it is also an essential limitation in designing efficient strategies for lung imaging. Using intravascular injections of a superparamagnetic contrast agent in rats, it was possible to increase the overall susceptibility of the perfused lung tissues and hence to match it with the gas susceptibility. The transverse decay time constant of inhaled hyperpolarized helium‐3 was measured in multiple‐spin‐echo experiments at 1.5 T as a function of the superparamagnetic contrast agent concentration in the animal blood. The time constant was increased by a factor of 3 when an optimal concentration was reached as predicted for susceptibility matching by combining intrinsic susceptibilities of tissue, blood, and gas. Magn Reson Med 54:28–33, 2005. Published 2005 Wiley‐Liss, Inc.Keywords
This publication has 23 references indexed in Scilit:
- MRI for the diagnosis of pulmonary embolismJournal of Magnetic Resonance Imaging, 2003
- In‐vivo visualization of phagocytotic cells in rat brains after transient ischemia by USPIONMR in Biomedicine, 2002
- Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imagingEuropean Radiology, 2001
- Detection of emphysema in rat lungs by using magnetic resonance measurements of 3 He diffusionProceedings of the National Academy of Sciences, 2000
- Information on the Scientific ProgrammeEuropean Radiology, 1999
- Magnetic Susceptibility Measurements of Solid Manganese Compounds with Evan's BalanceJournal of Chemical Education, 1996
- Double-bracelet resonator Helmholtz probe for NMR experimentsReview of Scientific Instruments, 1995
- Susceptibility changes following bolus injectionsMagnetic Resonance in Medicine, 1993
- MRI susceptometry: Image‐based measurement of absolute susceptibility of MR contrast agents and human bloodMagnetic Resonance in Medicine, 1992
- Distribution of Blood (Fe 59 ) and Plasma (I 131 ) Volumes of Rats Determined by Liquid Nitrogen FreezingCirculation Research, 1956