Evaluation of the BinaxNOW Staphylococcus aureus Test for Rapid Identification of Gram-Positive Cocci from VersaTREK Blood Culture Bottles
- 1 September 2013
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 51 (9) , 2939-2942
Abstract
The ability of the rapid BinaxNOW Staphylococcus aureus (BNSA) immunochromatographic test (Alere Scarborough, Inc., ME) to accurately differentiate S. aureus from coagulase-negative staphylococci (CoNS) and other Gram-positive cocci (GPC) directly from VersaTREK blood culture bottles was evaluated. A total of 319 positive patient blood culture bottles with GPC seen in clusters with Gram staining were tested using the BNSA test and a direct tube coagulase test (DTCT). The BNSA test was accurate for the detection and differentiation of S. aureus from CoNS and other GPC within 30 min from the time of blood culture positivity and demonstrated a test sensitivity and specificity of 95.8% and 99.6%, respectively. BNSA test results were faxed to the antimicrobial stewardship pharmacist by noon each day in order to evaluate empirical antimicrobial therapy and facilitate more rapid changes or modifications if necessary. Same-day reporting of BNSA test results in conjunction with an antimicrobial stewardship program was more impactful in improving treatment for inpatients with documented S. aureus bacteremia than in reducing empirical vancomycin use in inpatients with CoNS during the first 24 h following reporting.Keywords
This publication has 14 references indexed in Scilit:
- Clinical Impact of a Real-Time PCR Assay for Rapid Identification of Staphylococcal BacteremiaJournal of Clinical Microbiology, 2012
- Evaluation of the Xpert™ MRSA/SA Blood Culture assay for the detection of Staphylococcus aureus including strains with reduced vancomycin susceptibility from blood culture specimensDiagnostic Microbiology and Infectious Disease, 2011
- Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture systemIndian Journal of Medical Microbiology, 2011
- An Antimicrobial Stewardship Program’s Impact with Rapid Polymerase Chain Reaction Methicillin‐ResistantStaphylococcus aureus/S. aureusBlood Culture Test in Patients withS. aureusBacteremiaClinical Infectious Diseases, 2010
- Performance of two tube coagulase methods for rapid identification of Staphylococcus aureus from blood cultures and their impact on antimicrobial managementClinical Microbiology and Infection, 2008
- Rapid Identification of Staphylococcus aureus in Blood Cultures by Use of the Direct Tube Coagulase TestJournal of Clinical Microbiology, 2007
- Impact of rapid in situ hybridization testing on coagulase-negative staphylococci positive blood culturesJournal of Antimicrobial Chemotherapy, 2006
- Septic shockThe Lancet, 2005
- Evaluation of Three Rapid Methods for the Direct Identification of Staphylococcus aureus from Positive Blood CulturesJournal of Clinical Microbiology, 2003
- Direct Identification of Staphylococcus aureus from Positive Blood Culture BottlesJournal of Clinical Microbiology, 2003