Evaluation of a Mandatory Quality Assurance Data Capture in Anesthesia
Authors:
- Robert A. PeterfreundRPRobert A. Peterfreund
- William D. DriscollWDWilliam D. Driscoll
- John L. WalshJWJohn L. Walsh
- Aparna SubramanianASAparna Subramanian
- Shaji AnupamaSAShaji Anupama
- Melissa WeaverMWMelissa Weaver
- Theresa MorrisTMTheresa Morris
- Sarah ArnholzSASarah Arnholz
- Hui ZhengHZHui Zheng
- Eric T. PierceEPEric T. Pierce
- Stephen F. SpringSSStephen F. Spring
- 1 May 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 112 (5) , 1218-1225
Abstract
Efforts to assure high-quality, safe, clinical care depend upon capturing information about near-miss and adverse outcome events. Inconsistent or unreliable information capture, especially for infrequent events, compromises attempts to analyze events in quantitative terms, understand their implications, and assess corrective efforts. To enhance reporting, we developed a secure, electronic, mandatory system for reporting quality assurance data linked to our electronic anesthesia record. We used the capabilities of our anesthesia information management system (AIMS) in conjunction with internally developed, secure, intranet-based, Web application software. The application is implemented with a backend allowing robust data storage, retrieval, data analysis, and reporting capabilities. We customized a feature within the AIMS software to create a hard stop in the documentation workflow before the end of anesthesia care time stamp for every case. The software forces the anesthesia provider to access the separate quality assurance data collection program, which provides a checklist for targeted clinical events and a free text option. After completing the event collection program, the software automatically returns the clinician to the AIMS to finalize the anesthesia record. The number of events captured by the departmental quality assurance office increased by 92% (95% confidence interval [CI] 60.4%–130%) after system implementation. The major contributor to this increase was the new electronic system. This increase has been sustained over the initial 12 full months after implementation. Under our reporting criteria, the overall rate of clinical events reported by any method was 471 events out of 55,382 cases or 0.85% (95% CI 0.78% to 0.93%). The new system collected 67% of these events (95% confidence interval 63%–71%). We demonstrate the implementation in an academic anesthesia department of a secure clinical event reporting system linked to an AIMS. The system enforces entry of quality assurance information (either no clinical event or notification of a clinical event). System implementation resulted in capturing nearly twice the number of events at a relatively steady case load.Keywords
This publication has 18 references indexed in Scilit:
- "Every error counts": a web-based incident reporting and learning system for general practiceQuality and Safety in Health Care, 2008
- Critical incident monitoring in anaesthesiaCurrent Opinion in Anaesthesiology, 2008
- Rates and types of events reported to established incident reporting systems in two US hospitalsQuality and Safety in Health Care, 2007
- Lag time in an incident reporting system at a university hospital in JapanQuality and Safety in Health Care, 2007
- Integrating Incident Reporting into an Electronic Patient Record SystemJournal of the American Medical Informatics Association, 2007
- Sensitivity of routine system for reporting patient safety incidents in an NHS hospital: retrospective patient case note reviewBMJ, 2006
- Changing Medical Group Behaviors: Increasing the Rate of Documentation of Quality Assurance Events Using an Anesthesia Information SystemAnesthesia & Analgesia, 2006
- Intraoperative Tachycardia and Hypertension Are Independently Associated with Adverse Outcome in Noncardiac Surgery of Long DurationAnesthesia & Analgesia, 2002
- Intraoperative Tachycardia and Hypertension Are Independently Associated with Adverse Outcome in Noncardiac Surgery of Long DurationAnesthesia & Analgesia, 2002
- Factors Influencing the Reporting of Adverse Perioperative Outcomes to a Quality Management ProgramAnesthesia & Analgesia, 2000