Transthoracic left ventricular puncture for the assessment of patients with aortic and mitral valve prostheses: The Massachusetts General Hospital experience, 1989-2000
- 17 March 2003
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (4) , 539-544
Abstract
Accurate assessment of suspected prosthetic valve dysfunction is critically important as reoperation carries high risk. Noninvasive methods of hemodynamic assessment of patients with both aortic and mitral mechanical valves continue to be frustrated by the interference created by prosthetic material and direct left ventricular puncture may be required for definitive hemodynamic assessment. We report the hemodynamic and angiographic results and outcomes of 38 consecutive patients with double valve replacement who underwent left ventricular puncture as part of evaluation of possible prosthetic dysfunction. These results were compared with those obtained by noninvasive testing. We found noninvasive assessment alone to be unsatisfactory as measurements of regurgitation and stenosis correlated poorly with those obtained by direct left ventricular puncture. Important information that altered patient management was obtained from invasive assessment in 68% of cases with an acceptable rate of complications. Therefore, hemodynamic and angiographic assessment using transthoracic left ventricular puncture should be entertained in patients with mitral and aortic valve replacement presenting with congestive heart failure and suspected prosthesis dysfunction.Keywords
This publication has 25 references indexed in Scilit:
- Summary of the Mayo clinic experience with direct left ventricular punctureCatheterization and Cardiovascular Diagnosis, 1998
- Hemodynamic rounds series II: Left ventricular puncture for hemodynamic evaluation of double prosthetic valve stenosisCatheterization and Cardiovascular Diagnosis, 1998
- Left heart catheterization by direct puncture with two‐dimensional echocardiographic guidance: A case reportCatheterization and Cardiovascular Diagnosis, 1995
- Multiplane Transesophageal Echocardiography: Image Orientation, Examination Technique, Anatomic Correlations, and Clinical ApplicationsMayo Clinic Proceedings, 1993
- Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation.Circulation, 1991
- Clinical experience with the Medtronic-Hall valve prosthesisThe Annals of Thoracic Surgery, 1990
- Transesophageal Echocardiography: Technique, Anatomic Correlations, Implementation, and Clinical ApplicationsMayo Clinic Proceedings, 1988
- Reoperation for Prosthetic Heart Valve ReplacementThe Thoracic and Cardiovascular Surgeon, 1986
- Doppler Echocardiography: Theory, Instrumentation, Technique, and ApplicationMayo Clinic Proceedings, 1985
- The Surgical Management of Mitral Valve Disease: A Symposium on Diagnostic Methods, Operative Techniques, and ResultsAnnals of Internal Medicine, 1964