Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures
Open Access
- 29 October 2018
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 272
Abstract
In the present study, we evaluated the mechanical outcome of different configurations formed by fully threaded screws and partially threaded screws in the treatment of unstable femoral neck fracture. The Pauwels type III unstable femoral fracture and the models of the fully threaded screw and partially threaded screw were constructed in 3-matic software and UG-NX software respectively. We then assembled the different screw configurations to the fracture model separately to form the fixation models. After meshing the models’ elements, we used Abaqus software to perform the finite element analysis. Parameters of von Mises stress distribution on the screws, peak stress, displacement between fracture fragments, and model principal strains in cancellous bone were reported. Our results indicated that the peak von Mises stresses of screws was concentrated in the middle surface of the screw near the fracture line in each group. Peak stress value of the implants was highest in the model of triangle with posterior single screw. And the lowest stress values were observed in the triangular model. Fully threaded screw in each group underwent the most stress while partially threaded screw underwent a little bit of stress. Lowest displacement was observed in the triangular model. The volume of bone susceptible to yielding in the femoral neck region was the lowest for triangular configuration. For unstable femoral neck fractures, superior results were obtained by stabilizing the fracture with triangular configuration formed by one superior partially threaded screw and two inferior fully threaded screws. This study will require clinical confirmation as to its practicality in the management of unstable femoral fractures.Keywords
This publication has 25 references indexed in Scilit:
- Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fracturesArchives of orthopaedic and trauma surgery, 2018
- A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fracturesInternational Orthopaedics, 2018
- Dynamic locking plate vs. simple cannulated screws for nondisplaced intracapsular hip fracture: A comparative studyInjury, 2016
- Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fracturesInjury, 2015
- Experimental validation of finite element model for proximal composite femur using optical measurementsJournal of the Mechanical Behavior of Biomedical Materials, 2013
- The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: A subject‐specific finite element studyJournal of Orthopaedic Research, 2012
- Hip fracture incidence is decreasing in the high incidence area of Oslo, NorwayOsteoporosis International, 2012
- Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia ModelsAnnals of Biomedical Engineering, 2010
- Structural properties of fourth-generation composite femurs and tibiasJournal of Biomechanics, 2008
- Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysisClinical Biomechanics, 2004