Quantitation of Mixtures of Diprotic Organic Acids by FT-IR Flow Titrations and Multivariate Curve Resolution
Authors:
- 1 January 2002
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 56 (1) , 40-50
Abstract
The combination of FT-IR flow titrations and second-order calibration methods is assessed for the first time as a potential method for quantifying mixtures of organic acids. FT-IR spectral information is richer and more specific than that provided by other spectrometric techniques. Also, the flow titration of the sample allows the use of second-order data analysis methods, such as multivariate curve resolution, which can quantify multianalyte systems using pure analyte standards in the presence of unknown interferents. Problems linked to FT-IR flow titrations, such as the impossibility of using buffer substances and the presence of major baseline contributions in the measurements due to changes in the water structureless absorption, have been overcome through the design of an adapted experimental setup and the use of second derivative spectra. Malic and/or tartaric acid are the model substances chosen to be quantified in the presence or absence of interferents. Both substances are diprotic acids with similar p K a values and, therefore, similar pH-dependent evolution. Samples with one or both acids with their related standards in the presence or absence of an inert interferent (sugar) are successfully resolved and quantified for a wide range of [analyte]: [interferent] ratios with no need for pH control in the process. These results suggest this methodology as an optimal and robust alternative for routine analysis.Keywords
This publication has 50 references indexed in Scilit:
- Sequential injection Fourier transform infrared spectroscopy for the simultaneous determination of organic acids and sugars in soft drinks employing automated solid phase extractionAnalytica Chimica Acta, 2000
- Sheath-flow Fourier transform infrared spectrometry for the simultaneous determination of citric, malic and tartaric acids in soft drinksAnalytica Chimica Acta, 2000
- Analytical Application of pH-Gradients in Flow Injection Analysis and Related TechniquesReviews in Analytical Chemistry, 2000
- Spectrophotometric determination of pKa values based on a pH gradient flow-injection systemAnalytica Chimica Acta, 2000
- Flow-through sensors for enhancing sensitivity and selectivity of FTIR spectroscopy in aqueous mediaVibrational Spectroscopy, 1999
- Multivariate curve resolution applied to continuous-flow spectrophotometric titrations. Reaction between amino acids and 1,2-naphthoquinone-4-sulfonic acidAnalytical Chemistry, 1995
- Continuous flow titration system for the generation of multivariate spectrophotometric data in the study of acid—base equilibriaAnalytica Chimica Acta, 1995
- Self-modelling curve resolution analysis of synchronous fluorescence spectroscopy data for characterization of acid mixtures and study of acid–base equilibriaThe Analyst, 1995
- Multivariate curve resolution applied to liquid chromatography—diode array detectionTrAC Trends in Analytical Chemistry, 1993
- The resolution of overlapping chromatographic peaks by evolving factor analysisAnalytica Chimica Acta, 1986