XPS analysis of glassy carbon electrodes chemically modified with 8‐hydroxyquinoline‐5‐sulphonic acid
- 30 December 2011
- journal article
- research article
- Published by Wiley in Surface and Interface Analysis
- Vol. 44 (4) , 491-496
Abstract
Glassy carbon (GC) modified electrodes were obtained by cycling the potential in an 8‐hydroxyquinoline‐5‐sulphonic acid (HQSA) solution. These electrodes were successfully tested as sensors of some species of alimentary and pharmaceutical interest, showing improved performances with respect to those of unmodified GC electrodes and of GC electrodes cycled under the same experimental conditions but in the absence of HQSA. As a matter of fact, in the wide potential range explored for modifying the electrodes, even in the absence of HQSA, complex redox processes leading to the production of several functional groups take place at the surface of glassy carbon itself. An XPS investigation was consequently performed to better understand the effective nature of active species present on the surface of HQSA modified electrodes. The spectroscopic experiments involved acquiring survey and detailed scans of an HQSA powder standard sample and of GC electrodes cycled both in the presence and in the absence of HQSA. The experimental value of the binding energy of the S2p 3/2 level of HQSA‐modified electrodes was found equal to that of the HQSA standard powder, thus confirming that HQSA molecules are adsorbed on the surface of the GC/HQSA electrodes and that they maintain their chemical structure and properties. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 26 references indexed in Scilit:
- A New Voltammetric Sensor Based on a Glassy Carbon Electrode Modified with 8‐Hydroxyquinoline‐5‐sulfonic AcidElectroanalysis, 2011
- Determination of Theophylline at a Cysteic Acid Modified Glassy Carbon ElectrodeElectroanalysis, 2009
- Structural studies of electrochemically activated glassy carbon electrode: Effects of chloride anion on the redox responses of copper depositionElectrochimica Acta, 2007
- Determination of Caffeine at a Nafion‐Covered Glassy Carbon ElectrodeElectroanalysis, 2007
- Electrochemical Determination of Meloxicam in Pharmaceutical Preparation and Biological Fluids Using Oxidized Glassy Carbon ElectrodesChemical and Pharmaceutical Bulletin, 2007
- Determination of Patent Blue V (E131) at a Nafion‐Modified Glassy Carbon ElectrodeElectroanalysis, 2006
- Electrochemical measurements of Cu2+ ions adsorbed on an electrochemically oxidized glassy carbon electrodeJournal of Electroanalytical Chemistry, 2003
- Uptake of ions by electrochemically treated glassy carbonAnalytical Chemistry, 1988
- Surface analysis of semiconductor-incorporated polymer systems. 1. Nafion and cadmium sulfide-NafionThe Journal of Physical Chemistry, 1985
- Hartree-Slater subshell photoionization cross-sections at 1254 and 1487 eVJournal of Electron Spectroscopy and Related Phenomena, 1976