Transient Hot‐Strip Method for Simultaneous Determination of Thermal Conductivity and Thermal Diffusivity of Refractory Materials
Author:
- 8 March 1991
- journal article
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 74 (3) , 650-653
Abstract
The transient hot‐strip method has been used for determining thermal conductivity and thermal diffusivity of a refractory brick. The technique is based on recording the transient temperature increase of a 25‐μm‐thick, 8‐mm‐wide, and 70‐mm‐long iron strip clamped between two sample halves and heated with a constant direct current. The method is accurate to within 5% in the thermal conductivity and to within 10% in the thermal diffusivity in the temperature range 20° to 700°C.Keywords