Frameless stereotactic body radiation therapy for multiple lung metastases
Open Access
- 8 July 2014
- journal article
- case report
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (4) , 105-116
Abstract
Two patients with multiple lung metastases (≥ 5) were treated using frameless stereotactic body radiation therapy (SBRT) on an Elekta Axesse linear accelerator equipped with an interdigitation‐capable multileaf collimator and four‐dimensional cone‐beam CT (4D CBCT). The technique and the early clinical outcomes were evaluated. Patient A with five lung metastases and Patient B with seven lung metastases underwent SBRT (48 Gy/8 fractions for Patient A, 42 Gy/7 fractions for Patient B). The treatments were administered using a 6 MV photon beam. The nominal dose rate was 660 MUs/min. Patients were positioned and immobilized using thermoplastic masks and image guidance was done using 4D CBCT. The targets were delineated on the images of the 4D CT, and the positron emission tomography‐computed tomography (PET‐CT) images were taken as references. A two‐step, volumetric‐modulated arc therapy (VMAT) plan was designed for each patient. Step 1: the lesions in one lung were irradiated by a 210° arc field; Step 2: the rest of the lesions in the other lung were irradiated by a 120° arc field. Plans were evaluated using conformity index (CI) and homogeneity index (HI). Patients were followed up and adverse events were graded according to the Common Terminology Criteria for Adverse Events v4.0 (CTCAE v4.0). The beam‐on time of each treatment was less than 10 min. The CI and HI for the two plans were 0.562, 0.0709 and 0.513, 0.0794, respectively. Pulmonary function deteriorated slightly in both patients, and the patient with seven lung lesions was confirmed to have Grade 1 radiation pneumonitis. The technique was fast, accurate, and well tolerated by patients, and the two‐step plan is a helpful design in reducing the dose to the lungs.PACS numbers: 87.55‐x, 87.56.J‐, 87.56.‐v, 87.56.nk, 87.57.qpKeywords
Funding Information
- Department of Health, Jiangsu Province, China (H201350)
This publication has 24 references indexed in Scilit:
- Predictive Factors for Radiation Pneumonitis in Lung Cancer Treated with Helical TomotherapyCancer Research and Treatment, 2013
- Segment Edit and Segment Weight Optimization: Two Techniques for Intensity Modulated Radiation Therapy and Their Application to the Planning for Nasopharyngeal CarcinomaTechnology in Cancer Research & Treatment, 2013
- Image-Guided Robotic Stereotactic Radiation Therapy with Fiducial-Free Tumor Tracking for Lung CancerRadiation Oncology, 2012
- Stereotactic Body Radiation Therapy for Patients With Lung Cancer Previously Treated With Thoracic RadiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung CancerJAMA, 2010
- Stereotactic body radiotherapy for stage I lung cancer and small lung metastasis: evaluation of an immobilization system for suppression of respiratory tumor movement and preliminary resultsRadiation Oncology, 2009
- Dose–volume modeling of the risk of postoperative pulmonary complications among esophageal cancer patients treated with concurrent chemoradiotherapy followed by surgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Investigation of clinical and dosimetric factors associated with postoperative pulmonary complications in esophageal cancer patients treated with concurrent chemoradiotherapy followed by surgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Respiratory correlated cone beam CTMedical Physics, 2005
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999